6. CHARGING

CAUTION
Notes
• Use the charger in locations where ambient temperature ranges from 0 to 40 ºC (32 to 104 ºF).
• Be sure to charge the WB-2000 battery before use.
• If the wireless microphone, and its WB-2000 rechargeable battery, has been left unused for 10
days or more, be sure to fully charge the battery before operating the microphone.
• Do not use the charger in locations subject to strong vibrations as poor electrical contact may
result, preventing correct charging.
• Do not frequently insert and remove the unit from the charger during charging as this could
degrade the WB-2000 battery performance.
• If the battery operating time is extremely short even when it has been fully charged, be sure to
replace it with a new WB-2000 as the battery has reached the end of its life.
Tip:
Under normal use condition, the battery can cycle through about 500 charges and discharges,
after which it will usually need to be replaced.
• Only recharge the microphone's battery after it has been completely exhausted.
(The wireless microphone can be continuously used for approximately 8 hours per recharging.)
Frequent battery charging following short-term use may accelerate battery exhaustion.
Step 1. Connect the optional AD-5000-2 AC adapter to the charger's power input terminal.
After connection, fit the cord into the charger's bottom slot to prevent the AC adapter plug
from accidentally slipping out of place. (See the next page, "Handling the power cord.")
Step 2. Connect the power cord to the AC adapter, then to an AC wall outlet.
Step 3. Set the charger's power switch to ON.
The power indicator will light.
Step 4. Turn off the power switch of the unit to be charged, then load the WB-2000 battery in the
unit.
For battery insertion instructions, please refer to the instruction manual enclosed with the
wireless microphone.
Step 5. Insert the WM-D5200 or WM-D5300 fully into the charger's rechargeable unit receptacle as
illustrated on the next page.
Ensure that the charging status indicator lights red.
Charging takes about 3 hours, after which the full-charge indicator lights green. (Charging
time may vary depending on remaining battery capacity when charging begins.)
Notes
• Do not move the wireless microphone during charging.
The battery may not fully or correctly charge due to disconnection from the charging
terminal's contacts.
• Be sure the wireless microphone is fully inserted into the charger.
• The WM-D5200 microphone can be charged while facing in any direction (front, back, left,
right).
• The DM-5300 microphone is designed to fit into the shape of the receptacle.
6
Avoid charging units installed with rechargeable batteries other
than the dedicated WB-2000 battery.
Charging any other than the specified battery could result in fire
or personal injury due to battery rupture.