OBJ_BUCH-1444-007.book Page 13 Thursday, June 9, 2016 1:34 PM
Digital Laser Measure
Dimensions
Degree of protection
A) The working range increases depending on how well the
laser light is reflected from the surface of the target (scat-
tered, not reflective) and with increased brightness of the la-
ser point to the ambient light intensity (interior spaces,
twilight). In unfavourable conditions (e.g. when measuring
outdoors at intense sunlight), it may be necessary to use the
target plate.
B) For measurements from the rear measuring-tool edge. In
unfavourable conditions (e. g. at intense sunlight or an insuf-
ficiently reflecting surface), a deviation influence of ±0.15
mm/m must be taken into account. In favourable conditions,
a deviation influence of ±0.05 mm/m must be taken into ac-
count.
C) In the continuous measurement function, the maximum
operating temperature is +40 °C.
D) The width of the laser line depends on the surface charac-
teristics and on the ambient conditions.
E) Less measurements are possible when using 1.2 V re-
chargeable batteries than with 1.5 V batteries. The battery
life listed refers to measurements without display illumina-
tion.
The measuring tool can be clearly identified with the serial
number 13 on the type plate.
Product Features
The numbering of the product features shown refers to the il-
lustration of the measuring tool on the graphic page.
1 Display
2 Measuring button
3 Button for area/surface, volume and indirect height
measurement (Pythagoras)
4 Delete / On/Off button **
5 Minus button
6 Button for selection of the reference level
7 Fixture for carrying strap
8 Plus button
9 Length and continuous measurement button
10 Battery lid
11 Laser beam outlet
12 Reception lens
13 Serial number
14 1/4" thread
15 Laser warning label
16 Latch of battery lid
17 Protective pouch
18 Tripod*
19 Laser viewing glasses*
Bosch Power Tools
20 Laser target plate*
GLM 50
* The accessories illustrated or described are not included as
53 x 114 x 30 mm
standard delivery.
IP 54 (dust and splash
** Keep button pressed to call up the extended functions.
water protected)
Display Elements
a Measured-value lines
b Result line
c Measuring functions
d Laser, switched on
e Measurement reference level
f Temperature warning
g Battery low indicator
h "ERROR" indication
Assembly
Inserting/Replacing the Batteries
Using alkali-manganese or rechargeable batteries is recom-
mended for operation of the measuring tool.
Less measurements are possible when using 1.2 V recharge-
able batteries than with 1.5 V batteries.
To open the battery lid 10, press the latch 16 and remove the
battery lid. Insert the batteries/rechargeable batteries. When
inserting, pay attention to the correct polarity according to
the representation on the inside of the battery compartment.
When inserting the batteries/rechargeable batteries, pay at-
tention to the correct polarity according to the representation
on the inside of the battery compartment.
When the battery symbol
display, at least 100 individual measurements are still possi-
ble. The continuous measurement mode is deactivated.
When the battery symbol
able batteries must be replaced. Measurements are no longer
possible.
Always replace all batteries/rechargeable batteries at the
same time. Do not use different brands or types of batter-
ies/rechargeable batteries together.
Remove the batteries/rechargeable batteries from the
measuring tool when not using it for longer periods.
When storing for longer periods, the batteries/rechargea-
ble batteries can corrode and self-discharge.
English | 13
Length measurement
Continuous measurement
Area/surface measurement
Volume measurement
Simple Pythagoras Measurement
appears for the first time on the
flashes, the batteries/recharge-
1 609 92A 1YM | (9.6.16)