Instruction for use
Wet and dry cleaning
Do not use the machine without the main filter installed. Use
dustbag when you are picking up dry material. Remove the
dust bag, before picking up liquids.
1 Handle assembly
The handle can be assembled at two
the brackets on the handle into the tubes on the cart. Insert the
screws through the holes in the two parts and secure them using
the hex nuts.
2 Start/Stop
3 How to remove the motor top
Turn off the machine and pull the plug out of the electrical outlet.
a) Open the clasp on each side of the motortop by pressing them
outwards. Lift the motor top by using the grip on top of the motor top.
b) Rest the motor top on a flat surface as illustrated.
Note! Remove the motor top if the machine is transported in a tilted
position. This is to prevent the machine from falling over.
4 Installing the dustbag
Fit the opening of the dustbag over the air inlet. Make sure the
cardboard piece has been pressed all the way past the raised
bumps on the air inlet. The flap on the cardboard piece is used to
close the dustbag when it is removed. Replace the motor top on the
tank.
5 Hose connection
Push the hose coupling in to the hose connection until it locks.
Press the button on the hose connection down to remove the hose.
6 Tools
The accessories may vary on different models.
a) Universal nozzle
Can be used on all types of flooring and for both wet and dry
pickup.
b) Crevice nozzle
Use to clean furniture, radiators and other hard to reach places.
c) Suction control
The suction control lets you regulate the air flow through the hose.
This is to prevent the nozzle from sticking to the surface vacuumed.
7 Accessory basket
Avaliable as an accessory. Hang it on the rear of the trolley, to
keep extra tools, detergents a.s.o..
8 Power cord storage
Wind up the cord starting at the machine. Store it on the hook on
the rear of the machine.
9 Wand assembly
Fit the sections together and twist to lock in place. Clean the nylon
inserts when needed. Separate the sections by pulling and twisting
at the same time.
10 Cleaning or exchanging filter
Turn off and unplug the machine.
a) Main filter: Open the filter cover by pressing the release button
and rotate the filter cover backwards. Remove the old filter and
insert the new or the cleaned filter. You can clean the filter by
brushing or shaking it or rinse it in water. Let the filter dry before you
reinstall it. Replace the filter when it is clogged and the suction
power is evidently decreased.
Note! Install the filter with the seal that surrounds the filter edge
upwards.
b) Pre-filter: Remove the main-filter, the pre-filter is located under-
neath it. The pre-filter is washable. Replace it when it is clogged
and the suction power is evidently decreased.
Note! If filter a and b are cleaned with water, let them dry
before reassembly.
All manuals and user guides at all-guides.com
c) Exhaust filter: At the lower left of the filter grid there are two
indicator windows. When the filter piece that shows in the indicator
window to the right looks dirty it is time to exchange the filter.
Remove the filter holder by pressing the button on top of it. Change
the filter by grabbing the filter flap and remove it from the holder.
Insert the new filter. Make sure the filter is inserted correctly, the
longest side down and the flap to the right. Reinsert the filter holder
and snap it in place.
d) HEPA-filter: This filter purifies the exhaust air from 99.99% of all
particles larger than 0.3 microns.
different heights. Insert
Open the filter cover as in 10a. Remove the filter cover by pulling
one side of the filter cover upward/forward until the filter cover
comes off. Exhange the filter when it is clogged and the suction
power is evidently decreased.
Install: Push the filter into the cover as illustrated, with the HEPA
label on the filter pointing at you.
Then press the HEPA-filter forward until the hooks snap in place.
Make sure the HEPA-filter is secured under the front edge of the
cover.
To remove: Push downwards/backwards on the HEPA-filters rear
edge until it snaps out.
11 Draining the tank
When the water level in the tank reaches maximum the float valve
will shut off the air flow through the machine. You will then hear
noticable change of the sound from the motor and notice that the
suction power decreases. When this occurs, switch the machine
off. Disconnect the machine from the power supply. Remove the
motor top according to earlier instruction (3). Always empty and
clean the tank after picking-up liquids. Allow all parts to dry
thoroughly before the motor top is reassembled.
a) Drain into a floor drain: Detach the drain hose from the cart.
Place the hose end near the floor drain and remowe the plug.
Replace the plug and secure the hose to the trolley when the tank
is drained.
b) Drain in a toilet, wash-basin, etc.:
Disconnect the suction hose. Grab the emptying grip on the front
side of the tank and tilt the tank and empty it through the spout.
13 Float valve
The machine is equipped with a float valve that shuts of the air flow
through the machine when the maximum fluid level is reached.
Clean the float valve when needed. Open the lid on the float valve
and remove the float body, wipe both the float valve and body with
a damp cloth.Reinstall the float body and close the lid.
Note! Never pick-up liquid without the float body in place in the
float. Always use a chemical defoamer when picking-up water
containing foaming detergents. Use a
defoamer recommended by the detergents manufacturer.