Possible faults

Before each fault elimination:
switch off device
wait for standstill of the saw blade
pull out mains plug.
After each fault clearance, put into operation and recheck all security installations.
Malfunction
Machine does not start after
switching on.
Machine stops while cutting.
Insufficient sawing capacity.
Traces of burns on the saw blade.
Saw vibrates.
Deceleration too slow (time to
dead stop >10 sec.).
Motor generates insufficient power
and becomes too hot.
Stiff height adjustment.
Stiff bevel cut adjustment.
In case of further faults or inquiries please contact your local dealer.

Technical specifications

Alternating-current motor
P
2.0 kW - P
1
S6 20% 5 min
Table dimensions
Table height
Cutting depth
No-load speed
Cutting depth
adjustment
Bevel cut adjustment
Mains voltage
Carbide tipped saw
blade
Weight
Connection diameter
for suction fitting
Year of construction
Possible cause
Power failure
Extension cable defective.
Motor protection switch has been tripped.
Motor or switch defect.
Jammed saw blade.
Saw blade is dull.
Rate of feed too high
Blunt saw blade.
Saw blade is warped.
Saw blade not properly mounted.
Motor brake defective.
Brake disk worn.
Three-phase motor is running on the
second phase.
Extension cable too long or cable cross-
section too small.
Blunt saw blade.
M6 nut (Fig. 17 of the assembly
instructions) too firmly tightened.
Dirty thread spindle.
Guiding parts do not slide in the driving link
(Fig. 24 of the assembly instructions).
Alternating-current motor
1.3 kW
P
2.5 kW - P
2
1
S6 20 %
2800 rpm
230 VAC
40 kg
Corrective action
Check the fuse.
Check cables; do not go on using defective cables.
Switch on again after the motor has cooled down.
Have motor or switch checked by an professional
electrician or replaced by original spare parts.
Remove table insert and unscrew the chip box lid and
eliminate the cause.
Replace saw blade (38).
Allow motor to cool and proceed working with less
pressure.
The saw blade must be resharpened or replaced.
Replace saw blade.
Mount saw blade properly.
Have the brake repaired by the customer service point
designated by us or by the manufacturer (us).
The fuses and the supply lines must be checked by an
electrician.
See "Start-up".
The saw blade must be resharpened or replaced.
Release slightly.
Clean and oil.
Oil the guiding parts.
Alternating-current motor
1.7 kW
P
3.0 kW - P
2
1
S6 20 %
800 x 550 mm
810 mm
approx. 90 mm
continuous
continuous
∅ 315 x 3.0/2.2 x 30 mm, 40 teeth
41.5 kg
100 mm
see last page
18
Three-phase motor
2.1 kW
P
3.3 kW - P
2
1
S6 20 %
2730 rpm
46 kg
2.5 kW
2
2680 rpm
400 VAC
43 kg

Publicidad