1. General Information

&hgjhjhgj&Troubleshootin
Before Installation, read the following instructions carefully. Each Liberty pump is individually factory tested to assure proper
performance. By closely following these instructions, potential operating problems should be eliminated, providing years of
gTroubleshooting&Troubl
trouble-free service.
eshooting&Troubleshootin
Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments.
g&Troubleshooting&Trou
The electrical connections and wiring for a pump installation should only be made by qualified personnel.
This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric
bleshooting&Troubleshoot
shock, be certain that it is connected only to a properly grounded, grounding-type 15 Amp receptacle.
Always wear rubber boots when water is on the floor and you must unplug the pump.
ing
DO NOT bypass grounding wires or remove ground prong from attachment plugs.
DO NOT use an extension cord.
This pump requires a separate, properly fused and grounded branch circuit. Make sure the power source is properly sized
for the voltage and amperage requirements of the pump, as noted on the nameplate.
The electrical outlet shall be within the length limitations of the pump power cord, and at least 4 feet above floor level to
minimize possible hazards from flood conditions.
The installation must be in accordance with the National Electric Code, Uniform Plumbing Code, International Plumbing
Code, as well as all applicable local codes and ordinances.
Sump and sewage pumps often handle materials which could cause illness or disease. Wear adequate protective clothing
when working on a used pump or piping.
Keep clear of suction and discharge openings. To prevent injury, never insert fingers into pump while it is plugged in.
DO NOT use this product for flammable or corrosive liquid.
DO NOT use this product in applications where human contact with the pumped fluid is common (such as swimming pools,
fountains, etc.)
NEVER dispose of materials such as paint thinner or other chemicals down drains, as they can chemically attack and
damage pump components, potentially causing product malfunction or failure.
DO NOT use pumps in water over 140F (60C).
DO NOT use pumps in mud, sand, cement, oil or chemicals.
DO NOT modify the pump in any way.
DO NOT lift or carry pump by power cord.
DO NOT remove any tags from pump or cords.
If pump is installed during construction before power is available, it must be protected from the environment to prevent
water from entering through the cord plug end, etc.

2. Sump Pit

&hgjhjhgj&Troubleshootin
A sump pit not less than 14" in diameter is recommended. A larger diameter pit is preferred as it allows for longer pump cycling
gTroubleshooting&Troubl
and reduced switch cycling. The minimum depth of the pit should be 18".
The bottom of the pit should be a solid level of bricks or concrete. DO NOT place the pump directly on earth, gravel or debr is
eshooting&Troubleshootin
since this can cause excessive wear of the impeller and possible jamming. "The Brick" (sold by Liberty Pumps as part #
4445000) is a pre-molded stable platform designed to fit your submersible pump. It raises the pump 2.75" off the bottom of the
g&Troubleshooting&Trou
pit, reducing the potential for jamming from rocks and debris. Contact your local distributor to order. Remove all debris from the
bottom of the sump pit before installation of the pump. A sump pit cover is suggested for safety and to prevent foreign objects
from entering the pit.