TYPICAL SYSTEM CONFIGURATION
(1) Drive with control unit
(2) Control unit (if installed externally)
(3) Light barrier transmitter
(4) Light barrier receiver
(5) Flashing lamp
(6) Antenna (optional)
(7) Key-operated switch (optional)
(8) Light barrier (optional)
(9) Light barrier (optional)
1
3
8
2
INSTALLATION
(1) F1
(2) F2
(3) F3
(4) C
(5) B
(6) M5
(7) A
(8) LED 5
(9) LED 6
(10) LED 4
(11) LED 3
(12) LED 2
(13) LED 1
(14) LED 7
(15) M1 ÷ M4
(16) M6
(17) SW1
(18) TEST
1
16
17
15
709238B-GB
1
5
7
4
8
9
1
Main fuse (230 V)
Additional fuse 24 V AC
Central fuse (logic circuitry)
Brake
Pause (gate pauses when open)
Receptacle for radio (model 801719)
Opening and closing force
Limit switch monitoring
Limit switch monitoring
Light barrier (monitoring)
B button input
A button input
STOP (emergency stop)
Diagnostics (general)
Terminal connection
Accessory connection (not required)
Program switch (DIP switch)
Test button (opens gate completely)
2
3
F2
F3
11
13
12
14
18
CONNECTIONS
M1
1- L
2- Earth
3- N (neutral conductor)
4- L
5- L
M2
6- L Close
7- N (neutral conductor)
8- L Open
9
M3
9- LED –
10- LED +
11- COM (common)
12- STOP (normally closed)
13- Button A (normally open)
14- Button B (normally open)
15- COM (common)
16- LS contact (normally closed) Light barrier connection
M4
17- OPEN (normally closed)
18- COM (common)
19- CLOSE (normally closed)
20- L
21- L
4
5
6
7
8
Flashing lamp
9
10
3x1,5mm
230V~ ±10% 50Hz
SUPPLY LINE
3
230Volt
L 230V/ 50Hz +/- 10%
Supply for control unit, drive,
accessories
230Volt~
Flashing lamp (230Volt~)
Drive connection 230 V AC, 700 VA
max.
Capacitor is connected
across 6 and 8
Gate status LED
Shows whether gate is OPEN or
CLOSED
Pedestrian button
A = open gate completely
B = open gate partially
Limit switch connection
Pre-installed for "right hand"
Accessories apply 24 V AC ±5%
500 mA
3x1,5mm
3x1,5mm
M
4
Opening
Closing
limit-stop
limit-stop
LIMIT SWITCHES