Delta DT2200P Manual De Instrucciones página 18

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
No or low
pressure
(initial use)
(continued)
Will not draw
chemicals
D25130
CAUSE
6.
Air in hose.
7.
Choke lever in the
"Choke" position.
8.
Throttle control lever is
not in the "Fast" position.
9.
High pressure hose is too
long.
1.
Wand not in low
pressure.
2.
Chemical filter clogged.
3.
Chemical screen not in
chemical
4.
Chemical too thick
5.
Pressure hose is too long
6.
Chemical build up in
chemical injector.
6.
7.
8.
9.
1.
2.
3.
4.
5.
6.
18- ENG
CORRECTION
Turn off the engine, then
the water source.
Disconnect the water
source from the pump
inlet and turn the water
source on to remove all air
from the hose. When there
is a steady stream of
water present, turn water
source off. Reconnect
water source to pump inlet
and turn on water source.
Squeeze trigger to remove
remaining air.
Move choke to the "No
Choke" position.
Move throttle control lever
to the "Fast" position.
Use high pressure hose
under 100 feet.
See How to Use Wand
paragraph in the
Operation Section.
Clean filter.
Insure end of chemical
hose is fully submerged
into chemical.
Dilute chemical. Chemical
should be the same con-
sistency as water.
Lengthen water supply
hose instead of pressure
hose.
Have parts cleaned or
replaced by AWSC.