Reer JANUS MJBOX Manual Del Usuario página 10

Módulos de interconexión
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

The MJB2 /MJB4 model has:
1. Lighted restart button and output status / weak signal led.
RESTART BUTTON –
OUTPUT STATUS LED
It is also possible to match the MJB2 and MJB4 models (without muting
lamp and override command) with muting light curtains as they are fitted
with the required settings.
If connecting an MJB1 or MJB3 model to a JANUS J series safety barrier
(without Muting function), the following connections must be disregarded:
SW1 (pins 1,2,3,4), CJ5, CJ7 (pins 7,8) and CJ9.
For the JANUS, MI, ML, MT versions use of a muting lamp (internal or
external) (0.5 5W) is obligatory for correct functioning of the light
curtains.
Where the risk analysis of the application requires it, the light curtain
permits connection of an external lamp to signal active Muting (0.5 5W).
Perform a check of the operation of this lamp periodically verifying its
turning on during the Muting or Override phase.
10
Figure 2 - MJB2/MJB4
CABLE
FAIRLEAD
TX
(Janus)
RX
8540705 • 18/12/2012 • Rev.6