Safety Information - Remington REM-40-GFA-O Manual Del Usuario E Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DANGER
WHAT TO DO IF THE SMELL OF GAS IS PRESENT:
DO NOT attempt to light the heater.
Extinguish any open flame.
Shut off gas to heater.
If odor continues, contact your local gas
supplier or fire department.
DO NOT touch or use any electric switch or
any electric device that can cause a spark.
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
If you can not reach your gas supplier, call the
fire department.
Service must be done by a qualified service
agency.
WARNING
NEVER store or use gasoline or other flammable
vapors and liquids in the vicinity of this heater.
NEVER store a propane (LP) cylinder not connected to
this heater in the vicinity of this heater.
NEVER connect heater to an unregulated gas supply.
NEVER obstruct the flow of combustion and ventilation
air. (The front and rear of heater).
NEVER use duct work in front or rear of heater.
NEVER modify this heater or operate a heater that has
been modified.
NEVER service, move or handle heater while still hot or
operating
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
Sides
Top
24 in.
36 in.
ALWAYS use the electrical power (voltage and frequency)
specified on the model plate of the heater.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
WARNING
DO NOT TOUCH. KEEP CHILDREN,
ANIMALS, CLOTHING AND
COMBUSTIBLES AWAY FROM HEATER.
© 2017, Pinnacle Climate Technologies, Inc.
BURNING, CONNECTED TO A POWER SOURCE, OR

Safety Information

PROPANE IS
AN EXPLOSIVE
GAS.
RISK OF BURNS,
FIRE AND
EXPLOSION!
Front
Rear
72 in.
24 in.
CAUTION!
HOT WHILE IN
OPERATION.
NEVER LEAVE HEATER UNATTENDED WHILE
WHILE CONNECTED TO A FUEL SOURCE
WARNING
WARNING
equipped with a three-prong (grounding) plug
for your protection against shock hazard and
should be plugged directly into a properly
grounded three-prong receptacle.
WARNING
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
Use heater in accordance with all local codes. In
the absence of local codes, refer to The National
Fuel Code, ANSI Z223.1.
This heater is shipped from the factory for use
with propane (LP) gas only. Do not convert to
any other gas. Installation must conform to local
codes, or in their absence, with the standard for
the Storage and Handling of Liquefied Petroleum
Gases ANSI/NFPA 58 and the Natural Gas and
Propane Installation Code CSA B149.1.
Gas supply connections should be checked by
using a 50/50 soap and water solution. Never use
a flame to check for gas leaks.
Locate LP cylinder at least 6 feet (10 ft. in
Canada) from the heater, and do not direct heater
discharge towards the LP cylinder unless it is at
least 20 feet from the heater.
Use only the regulator and hose assembly
provided with this heater. Inspect the regulator/
hose assembly prior to each use of the heater. If
there is excessive abrasion or wear, or if the hose
is cut, replace it with the proper assembly shown
in the parts list, prior to using the heater.
Minimum and Maximum Inlet Pressure
40-GFA
Min.
Max.
WARNING
material and contact with hot surfaces both
during use and while in storage.
Propane Forced Air Heater User's Manual
2
RISK OF
ELECTRIC
SHOCK!
Electrical Grounding
Instructions:
This appliance is
For use with
propane (LP)
gas only.
60V-GFA 125V-GFA 150V-GFA
5 PSI
Bottle Pressure
The hose assembly
shall be pro tected
from traffic, building

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rem-60v-gfa-oRem-125v-gfa-oRem-150v-gfa-o

Tabla de contenido