E N G L I S H
BREAKDOWNS TO THE STEAM IRON (IF FITTED)
1. Steam iron does not heat.
2. Steam iron overheating.
3. From the iron comes water
mixed with steam.
4. Steam overheated from the
iron.
BREAKDOWNS TO THE STEAM/AIR SPOTTING GUN (IF FITTED)
1. Steam
available
machine, but pushing the
gun
button
no
available from nozzle.
1. The exhaust fan does not
work.
C H A P T E R 4
1. Causes:
a) Break of cable continuity.
b) Iron resistance burned.
c) Iron
faulty.
2. Thermostat contacts faulty.
3. Causes:
a) Iron temperature too low.
b) In case of machine with
boiler check that water to
the
iron
suction
of the boiler itself.
4. Iron temperature too high.
to
the
1. Causes:
a) Micro-switch
steam
defective.
b) Break
continuity.
c) Solenoid valve coil burned.
EXHAUST FAN BREAKDOWNS
1. Causes:
a) Foreign objects block the fan.
b) The
pedal does not work.
c) The
burned out.
d) The motor is burned out.
thermostat
contacts
is
not
a
boiler
due
to
anomalies
contact
of
the
gun
cable
micro-switch
on
the
motor
condenser
is
Page 4-7
E N G L I S H
1. Action:
a) Repair the electric cable
continuity.
b) Replace
the
resistance.
c) Replace
the
and the fuse.
2. Replace the thermostat.
3. Action:
a) Rotate
the
thermostat
clockwise,
increasing
iron temperature.
b) See
"Breakdowns to the boiler"
4. Rotate the iron thermostat
handwheel
anticlockwise,
decreasing
the
temperature.
1. Action:
a) Check
the
contact and if necessary
replace it.
b) Check the continuity and
repair accordingly.
c) Replace burned coil.
1. Solutions:
a) Unblock
the
removing
the
bodies that are blocking
it.
b) Change
the
on the pedal.
c) Change
the
condenser.
d) Change the motor.
burned
thermostat
iron
handwheel
the
paragraph
iron
microswitch
fan
by
foreign
micro-switch
motor