Starting Up; Technical Characteristics; Operating Conditions; Checking - Zodiac RE/L Manual De Instalación Y De Uso

Ocultar thumbs Ver también para RE/L:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Figure 2
Single-phase power supply connection
Heater terminal
Protection with 30 mA differential
strip
circuit breaker at line head
clamps
Filtration
electric box
Single-phase power supply: 230Vac (S terminal) + Neutral (C
terminal) + Earth
5. STARTING-UP
Model
L-shaped heating electrical resistor power at nominal voltage
REL 3
REL 6
REL 9
REL 12
* with a manufacturer tolerance of ± 5 %
appliance protection index: IP 45

5.1 Operating conditions

The temperature of the water circulating in the exchanger must be between 2°C and 40°C.
Before switching the device on, you need to make sure:
• the hydraulic fittings are correctly tightened,
• there is no leak,
• the appliance is correctly fixed to the wall,
• the connections of the electric cables are correctly tightened,
Incorrectly tightened cables may cause overheating of terminals,
• the appliance is correctly connected to the Earth,
• the water contained in the appliance is not frozen,
In this case, it is interdict to put the heater under operation.
5.2 Starting-up
• switch on the filtration pump,
• check the degassing and water circulation in the heater,
• engage the protective 30 mA differential circuit breaker associated with the heater (or the fused
isolating switch with upstream a 30 mA differential circuit breaker),
• set the switch to the "on" position,
• adjust the control thermostat to the desired temperature.
Marks * to 6: * = 16°C ; 1 = 20°C ; 2 = 24°C ; 3 = 28°C ; 4 = 32°C ; 5 = 36°C ; 6 = 40°C
Note: the indicator of heating of orange color indicates that the device is heating the basin.

5.3 Checking

Make sure that the heater stops when:
• decreasing the required temperature on the control display (notice: when the temperature of the
water is below 16°C, the heater will always be operating, although it is set to "*"),
• filtration is switched off,
Phase Neutral
Earth
For the power cabl's cross section,
see table

Technical characteristics:

.
Figure 3
Three-phase power supply connection
Heater terminal
Protection with 30 mA differential
strip
circuit breaker at line head
Filtration
electric box
Three-phase power supply: 400Vac (R-S-T terminals) + Neutral (N
terminal) + Earth
3 kW*
6 kW*
9 kW*
12 kW*
4
Phases Neutral
Earth
For the power cabl's cross section,
see table
Weight
4 Kg
4 Kg
5 Kg
5 Kg

Publicidad

Tabla de contenido
loading

Tabla de contenido