Electrical Connections - CAME CASSA PS5000 Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34

7 Electrical connections

7.1 Cable list and minimum thickness
Connections
Control panel power supply
Control and safety devices
N.B.: If the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of the actual
power draw by the connected devices and depending on the standards specified in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw and
distances.When connecting products that are not specified in this manual, please follow the documentation provided with said products.
8 PSCA1 Card (PS5000 automatic cash register) – description
2
1
1 - Terminals to power the 230V A.C. Card
2 - Power supply safety fuse and F 5A heating element
3 - F 1A Control board circuit safety fuse
4 - "active circuit" signalling LED
5 - DIP Switch selector for programming the cash register
6 - Terminals to connect to the barrier
Type of cable
Length of cable 1 < 10 m
FROR CEI 20-22
3G x 1,5 mm
CEI EN
2 x 0,5 mm
50267-2-1
3
6
L. of cable 10 < 20 m
2
2
3G x 2,5 mm
2
2
2 x 0,5 mm
4
5
L. of cable 20 < 30 m
2
3G x 4 mm
2
2 x 0,5 mm

Publicidad

Tabla de contenido
loading