Descargar Imprimir esta página
Franklin Electric Little Giant 800 Manual Del Usuario
Franklin Electric Little Giant 800 Manual Del Usuario

Franklin Electric Little Giant 800 Manual Del Usuario

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Franklin Electric Co., Inc.
P . O. Box 12010
Oklahoma City, OK 73157-2010
Phone: 405-947-2511 • Fax: 405-947-8720
www.LittleGiantPump.com
CustomerService-WTS@fele.com
EN
This instruction sheet provides you with the information required to
safely own and operate your Little Giant filter. Retain these instruc-
tions for future reference.
The filter you have purchased is of the highest quality workmanship
and material, and has been engineered to give you long and reli-
able service. Our filters are carefully tested, inspected, and pack-
aged to ensure safe delivery and operation. Please examine your
filter carefully to ensure that no damage occurred during shipment.
If damage has occurred, please contact the place of purchase. They
will assist you in replacement or repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR
FILTER. KNOW THE FILTER'S APPLICATION, LIMITATIONS,
AND POTENTIAL HAZARDS. PROTECT YOURSELF AND
OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE!
SAFETY GUIDELINES
WARNING: Make sure that all submerged electrical components
are disconnected before performing any operation in the water. If
the plug or socket is wet, disconnect the breaker before removing
the power cord.
WARNING: To guard against injury, observe basic safety precau-
tions, including the following:
To avoid electric shock read the safety instructions.
This filter has no user-serviceable parts other than those described
in this instruction manual. Any service should be performed by an
authorized service representative.
Carefully examine the filter before installation. Do not operate the
filter if it is malfunctioning or appears otherwise damaged.
If the plug or receptacle is wet, disconnect the fuse or circuit break-
er before disconnecting the plug.
Keep children away from the filter.
Do not use the filter for anything other than its intended use.
The use of attachments not recommended or sold by the filter
manufacturer may cause an unsafe condition.
Do not install or store the filter where it will be exposed to tempera-
tures below freezing.
Max. pump flow • Débit max. de la pompe • Flujo máx. de la bomba
Max. pond size • Taille max. du plan d'eau • Tamaño máx. del estanque
Filter capacity • Capacité du filtre • Capacidad del filtro
Max. pressure at filter • La pression max. à la filtre • La máx. presión en
el filtro
PRESSURIZED FILTER
MODELS
800/1200/2400
ENGLISH
CAREFULLY
If the filter is not used during the winter months remove it to avoid
freezing.
Do not operate this filter in water hotter than 95°F (35°C).
Ensure that the filter is securely installed and stable before operat-
ing it.
BEFORE
This filter is designed to filter the water in small lakes and ponds,
and uses two types of filter media:
1. Mechanical filter media - High surface area sponge media
traps solid waste, maintaining clean and healthful water for both
fish and plants.
2. Biological filter media - Inert media (bio-balls) offer a large sur-
face area and high porosity that allow the development of ben-
eficial bacteria, which breaks down pollutants such as ammonia
and nitrites.
The pressurized filter carton contains:
Filter assembly
Bio-ball bags
O-ring
Owner's manual
Hardware kit
2 - 1" hose adapters
1 - handle
1 - cap
1 - O-ring (large)
2 - replacement hinges
1. Remove the filter assembly from the carton.
2. Loosen the 6 latches and remove the cover from the tank.
3. Remove the bottom plate from inside the tank, leaving the white
mesh grate in place.
Model 800
800 GPH
(3028 LPH)
800 USG
(3028 L)
5.3 USG
(20 L)
5.2 PSI
0.37 kg/cm
Table 1 • Tableau 1 • Tabla 1
DESCRIPTION
CONTENTS
ASSEMBLY
Model 1200
1200 GPH
(4542 LPH)
1200 USG
(4542 L)
6.6 USG
(25 L)
5.2 PSI
0.37 kg/cm
2
2
Model 2400
2400 GPH
(9084 LPH)
2400 USG
(9084 L)
8.0 USG
(30 L)
5.2 PSI
0.37 kg/cm
2
1

Publicidad

loading

Resumen de contenidos para Franklin Electric Little Giant 800

  • Página 1 PRESSURIZED FILTER MODELS Franklin Electric Co., Inc. P . O. Box 12010 800/1200/2400 Oklahoma City, OK 73157-2010 Phone: 405-947-2511 • Fax: 405-947-8720 www.LittleGiantPump.com CustomerService-WTS@fele.com ENGLISH This instruction sheet provides you with the information required to safely own and operate your Little Giant filter. Retain these instruc- tions for future reference.
  • Página 2 4. Remove the bio balls from their package(s) - separating any that c. Remove the inlet adapter and the cap on the outlet fitting and have become stuck together - and place them into the bottom swap their positions. of the tank around the outside of the white grate. d.
  • Página 3 d’instructions. Tout entretien doit être effectué par un électricien de DESCRIPTION service autorisé. Ce filtre est conçu pour filtrer l’eau des petits lacs et des petits étangs; il utilise deux types de médias filtrants : Examiner le filtre avec soin avant son installation. Ne pas faire fonctionner le filtre s’il fonctionne mal ou s’il est endommagé...
  • Página 4 • 1 capuchon 3. Enlever l’adaptateur de sortie et le capuchon de contre-courant et inverser leurs positions. • 1 joint torique (grand) 4. Brancher un tuyau de décharge à l’adaptateur du raccord de • 2 charnières de rechange contre-courant. ASSEMBLAGE 5.
  • Página 5 TERCEROS Y PROTÉJASE A USTED MISMO SIGUIENDO ENSAMBLADO TODA LA INFORMACIÓN DE SEGURIDAD. ¡LA FALTA DE 1. Saque el conjunto de filtro de la caja. CUMPLIMIENTO DE ESTAS INSTRUCCIONES PUEDE PRODUCIR 2. Afloje los 6 sujetadores y quite la tapa del tanque. LESIONES PERSONALES Y/O DAÑOS A LA PROPIEDAD! 3.
  • Página 6 3. Quite el adaptador de salida y la tapa de la salida de contracorriente e intercambie sus posiciones. 4. Conecte una manguera de desperdicios al adaptador del acople de contracorriente. 5. Conecte la bomba del estanque a la corriente eléctrica. Esto soltará...
  • Página 7: Garantie Limitée

    LIMITED WARRANTY GARANTIE LIMITÉE Your Little Giant product is guaranteed to be in perfect condition La présente garantit que votre pompe Little Giant est en parfaite when it leaves our Factory. It is warranted against defective materials condition à sa sortie de l’usine. La pompe est garantie contre tout and workmanship for a period of 36 months from date of purchase défaut de matériau ou de fabrication pendant une période de 36 by the user.
  • Página 8: Garantia Limitada

    Para partes o la reparación, por favor póngase en contacto ....1-888-572-9933 Para la ayuda técnica, por favor póngase en contacto ....... 1-888-956-0000 www.LittleGiantPump.com CustomerService-WTS@fele.com Form 998476 - 12/29/2009 ©2009 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.