1. Security Advice
Read and understand this instruc-
tion sheet prior to installation and
set-up of the unit.
Observe personal protection in
regard of chemical products dur-
ing refilling procedures (product
replacement), maintenance and
repair. Read product label and
MSDS sheet.
2. Description
The Penguin Foam is especially
suited for foam cleaning and disin-
fection using tap water in smaller
areas.
The unit is suited for use in rooms
with floor drains. The unit is
equipped with a Ca or Ba valve
depending on version, this makes
it an EN1717 approved equipment
and can be connected directly to
the water supply.
3. Location
The Penguin Foam must be placed
in a frost-free room only.
To ease the operation, leave as
much free space as possible
around the unit.
4. Water supply
Water quantity:
25 l/min. / 6.6 USG p.m.
Pressure:
2.5-7 bar / 250-700 kilopas-
cal/36-101 PSI
Max. temperature:
45°C/113°F
Connection:
1/2" external thread
Note: A closing valve must be
mounted directly before the
It must be expected that the foam
quality and the rinsing effect will be
reduced if the requirements to the
water supply are not met.
EN
*
Fig. 1
Taps, mixing batteries etc. may
have a limiting effect on the wa-
ter quantity. If one of these are
placed before the unit and the
water quantity is not sufficient, it is
re commended to replace it with a
ball valve. The replacement should
be carried out by an authorised
plumber.
unit.
* In case of flex hose connec-
tion, install non-return valve
type "ED"
5. Mounting
It is recommended to mount the
Penguin Foam in an appropriate
height, however, max. 4' 3" above
the floor on a moisture repellent
wall construction. The unit must be
placed so that the water inlet hose
can reach the connecting point.
Secure the Penguin Foam, Hose-
holder and Can holder on the wall
with the enclosed screws and
rawlplugs.
Note: Hose holder and Can holder
should be placed so that the can is
under the level of the unit.
0627293
3