23-11-2243N-003
WARNING
Electrical Shock Hazard
1. Plug unit only into grounded electrical outlet.
2. Do not use an extension cord or plug adaptor with
this unit.
3. Do not operate unit with front removed.
Failure to follow the above precautions could result in electrical
shock, fire or personal injury.
If the dehumidifier has a serial plate rating of 115 volts
and up to and including 7.5 amps the unit may be on a fuse
or circuit breaker with other devices. However, the maximum
amps of all devices on that fuse or circuit breaker can not exceed
the amps of the fuse or circuit breaker.
The location of the serial plate that applies to this model
can be found on the back page of this manual.
Notice
Do not operate this dehumidifier without proper time delay
circuit protection. Refer to serial plate for proper power
supply requirements.
RECOMMENDED CIRCUIT WIRE SIZES
(As installed per building code)
PROTECTOR SIZE
15 AMP
20 AMP
30 AMP
115V
230V
230V
15A
15A
20A
This dehumidifier has been carefully engineered, manufactured and tested to give you many years of comfort and dependable
operation.
THIS IMPORTANT INFORMATION tells you all you need to know about installing, using and caring for your new Dehumidifier. Keep
it handy, it will answer your questions, save you time and expense, and insure that, as the owner of this superb appliance, you receive
maximum comfort and enjoyment for many years.
Close Windows and Doors
To assure efficient dehumidification, close all windows
and doors in the area where the dehumidifier is to
operate.
Plug In
Once you have assembled your dehumidifier and
installed it in an appropriate location, plug the cord into
a properly grounded outlet as indicated in the electrical
requirement.
For Your Safety:
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance. The
fumes can create a fire hazard or explosion.
Power Supply:
Outlet Requirement: 3-Prong Grounding Type
Minimum Wire Size: #14 (A.W.G.) 3-Wire
Circuit Protector:
WIRE GAUGE
#14 MINIMUM
#12 MINIMUM
#10 MINIMUM
230V
30A
WARNING
115V, 60HZ
AC Only 1-Phase
125 V, 15 Amp
Use Copper Wire Only
15 Amp Time Delay Fuse
or Circuit Breaker
3
ELECTRICAL REQUIREMENTS
1. ELECTRICAL REQUIREMENTS
Grounded
1
three-prong
wall receptacle
Three-prong
grounding plug
Important
Grounding Requirements
Your Dehumidifier will operate on any 115
volt, 3-pronged (grounded), 60 Hz circuit. A
separate line is not required, but it is
advisable not to overload the circuit with
heavy duty appliances such as washing
machines, etc. For your safety, this
dehumidifier is equipped with a 3-pronged,
grounding plug and must be plugged into a
properly grounded outlet (Figs. 1 & 2). If
your outlet is not of the proper type, it is
your responsibility to have the outlet and
wiring changed to the correct type. DO
NOT cut off the third (grounding) prong.
DO NOT USE AN ADAPTER.
Single outlet
2
grounding
wall receptacle