Connections
For correct connection - see drawings "INSTALLATION".
• Use reliable cord end terminals to fix the wires to the
DC-input and –output.
• See specifications for the recommended wire size.
• To minimize any EMC-interference we advise to
connect the negative pole of the supplying battery to
the ground.
Connect a momentary switch between the "switch"-
connection and the DC-output ground if you want to use
the remote switch function and/or the light dimmer
function (see drawing 1B, 2B, 3B).
Alarm contact
The alarm contact, right side connection on the back
(see drawings "DIMENSIONS"), is connected to the
contact. The contact is activated and connected to the
output ground in a normal situation, and will be
deactivated if the input voltage is too low (default 10.0V
or 20.0V), if the input voltage is too high (default 16.0V
or 32.0V), in case of overload or short-circuit. The
contact is also deactivated when the MAGIC is switched
off.
Operation
The converter operates automatically. Under normal
circumstances, there is no need for operation. Despite
its low no-load consumption, the converter should be
disconnected from the supplying battery when it is not in
use to protect the battery from discharging.
Refer to table "SWITCH OPERATION" for explanation of
the remote switch function / dimmer operation.
SWITCH OPERATION
Short
Long
Extended functions
Via the "QRS232 communication port" various settings
can be adjusted in terms of software to your specific
demands (control software and interface not included).
Check the Internet site www.mastervolt.com for
applications. Please mind that this plug is not intended
for connecting any remote panels or a battery
temperature sensor.
Converter switches off.
Press again to switch
on.
After 1 sec. the output
voltage slowly
decreases to 4V or 8V.
Press again to increase
the voltage
ENGLISH
Battery charger
Three-stage charge curve: Stage A: BULK, for quick
charging from 0 to 80%, Stage B: ABSORPTION, the
battery is charged from 80 to 100%. Stage C: FLOAT,
battery is maintained in fully charged state.
Guarantee terms
Mastervolt guarantees that this converter was built
according to the legally applicable standards and
stipulations. During production and before delivery all
converters were exhaustively tested and controlled. If
you fail to act in accordance with the regulations,
instructions and stipulations in this user's manual,
damage can occur and/or the converter will not fulfil the
specifications. This may mean that the guarantee will
become null and void.
The guarantee period is 2 years.
Liability
Mastervolt cannot be held liable for:
• Consequential damage resulting from the use of the
converter.
• Possible errors in the included manual and the
consequences of these.
• Use that is inconsistent with the purpose of the
product