Further information
Important Notes:
LPG cylinder not provided. The appliance is
designed to operate with a cylinder of size Ø
31.8 x 58 cm.
This appliance requires a 15 kg butane LPG
cylinder or a 13 kg propane LPG cylinder.
Gas regulator should be the correct one and
be set according to specific gas category
(see Technical data on page 3).
Gas regulator should be approved according
to EN 12864 with proper capacity (g/h), pres-
sure, working temperature and inlet + outlet
connection for the country of destination.
The regulator illustrated on the manual is for
United Kingdom, the regulator in your country
maybe different with the one on the illustration.
Flexible gas rubber pipe should be approved
according to EN 1763-1 with proper inner Ø
to match pipe holders of gas circuit and gas
regulator, pressure and working tempera-
ture.
The length of the hose is 1.70 m and it
should not exceed 2.0 m. The hose shall be
readily visible across its entire length for
inspection after installation.
Danger:
You must have the proper regulator and
cylinder in order for the appliance to operate
safely and efficiently. Use of an incorrect or
faulty regulator is dangerous and will invali-
date any warranty.
Connect LP Gas cylinder
Before connecting, be sure that there is no
debris caught in the head of the LP tank,
head of the regulator valve or in the head
of the burner and burner ports.
Connect gas line to tank by turning knob
clockwise until it stops, make sure that the
tube is not subject to twisting.
After connecting to gas cylinder, a leak test-
ing is necessary.
Disconnect LP Gas cylinder
Before disconnecting make sure the LP gas
tank valve in "CLOSED". Disconnect gas line
from LP gas cylinder by turning knob
counterclockwise until it is loose.
For storage and cylinder exchange, discon-
nect hose at the cylinder only, DO NOT
disconnect hose from appliance.
To change the gas cylinder in an amply ven-
tilated area, away from any ignition source
(candle, cigarettes, other flame producing
appliances...).
6