Maintenance
•
When not in use the lifting arm and pump lever should be fully in the down position.
•
Regularly check the oil level (5):
- Place the jack on an even level surface.
- Open the release valve.
- The correct oil level is at the bottom of the thread inside the oil chamber when the lifting arm is at it's fully down
position.
- If lacking oil, remove the vent plug located under the cover, fill with good quality blended jack oil (SAE10) to the
correct level, replace and tighten the vent plug.
- Raise the lifting arm up to it's full height and then open the release valve; step on to the saddle and force the lifting
arm down as rapidly as possible. Repeat three to four times to ensure complete distribution of the oil.
- Close the release valve tightly and check that the jack works correctly under load.
•
Keep the jack clean, dry and ensure all moving parts are well lubricated using a light oil, lubricate the handle socket
and lifting arm with a suitable grease.
•
Grease the lift arm pivot using the grease nipple provided.
•
Should any part require replacement through normal use contact your Metalworks stockist for spare parts.
•
Before use check the jack for any signs of missing parts, cracking, damage or distortion - do not use if any damage
is found. Do not modify this product in any way.
®