Maintenance
When not in use the lifting arm and pump lever should be fully in the down position.
Regularly check the oil level (5):
- Place the jack on an even level surface.
- Open the release valve.
- The correct oil level is at the bottom of the thread inside the oil chamber when the lifting arm is at it's fully down
position.
- If lacking oil, remove the vent plug located under the cover, fill with good quality blended jack oil (SAE10) to the
correct level, replace and tighten the vent plug.
- Raise the lifting arm up to it's full height and then open the release valve; step on to the saddle and force the lifting
arm down as rapidly as possible. Repeat three to four times to ensure complete distribution of the oil.
- Close the release valve tightly and check that the jack works correctly under load.
Keep the jack clean, dry and ensure all moving parts are well lubricated using a light oil, lubricate the handle socket
and lifting arm with a suitable grease.
Grease the lift arm pivot using the grease nipple provided.
Should any part require replacement through normal use contact your Metalworks stockist for spare parts.
Before use check the jack for any signs of missing parts, cracking, damage or distortion - do not use if any damage
is found. Do not modify this product in any way.
®