Descargar Imprimir esta página

Carbest 800801 Manual De Funcionamiento página 16

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
OpERATing inSTRuCTiOnS
GB
NOT_CARBEST-00
EMC
Security
Housing
Mounting
Dimensions (mm)
Weight
Ac interface
Battery interface
T° sensor & carbus
interface
LED
Yellow
Flashing
yellow
Flashing
green
Green
Red
Flashing
red
Flashing
red (quick
flash)
Flashing
green
(quick
flash)
16
Aluminium type – wall mounted
3 points terminal
Pin_out auxiliary
connector:
1 - carbus
2 - com
3 - t° sensor
Mode
Absorption
Equalization
End
equalization
Floating
Internal
temperature
fault
Battery
temperature
fault
Output
voltage fault
Output fuse
Stand-by
12V 20A
EN61000-6-3 & EN61000-6-1
EN60335-2-29 (2002)
2 x 4mm screws
278 x 120 x 96
1.3 kg / 2.87lbs
3 x 1,5 mm
cable, lenght 1m
2
AWG12 cables, lenght 1m
Status
The battery is charging. Time required
to complete absorption mode var-
ies, depending on the initial sate of
charge of the battery. It is limited to
6 hours
The battery is coming to the end of
the charging cycle. Time required to
complete equalization mode var-
ies, depending on the initial sate of
charge of the battery. It varies from
30 minutes to 4 hours
The battery is almost charged. Float-
ing mode will begin in less than 30
minutes
The battery is completely charged
The charger is on standby mode for
a period of between 30 seconds to
10 minutes. Once the fault has been
solved, the charger restart automati-
cally
> Please check the ambient tem-
perature (charger and/or battery) as
well as the internal fan and the place
around the charger
The charger is on standby mode for a
period of 30 seconds. Once the fault
has been solved, the charger restart
automatically
> The electronic board has probably
failed and the damage is irreversible
The output fuse should be replaced
> Please check the battery's polarity
The charger is not charging (no main
or stand-by mode)
UK

Publicidad

loading