NFC STANDALONE ACCESS CONTROL MODULE
Continued from previous page.
Programming relay 1 activation time by card/ key tag access: set DIP
switch 5 to ON, the LED on the front will blink (red). Press and hold down
button P1, the red LED will turn off and the green LED will blink; each
blink will increase the minimum activation time of 3 seconds already set at
the factory by 1 second. Once the desired activation time has been
selected, stop pressing button P1, the module will then emit 2 short tones and the LED
will light up (green) for 1 second confirming the new activation time.
If you wish to reset the default time of 3 seconds, press button P1.
To exit "Relay 1 activation time with card/ key tag" mode, set DIP switch 5 to OFF, the LED
on the front (red) will turn off. Note: To adjust relay 2 activation time by card/ key tag
access, a mobile with NFC and AC Manager app is required (Android only).
INSTALLATION OF THE LOCK RELEASE
( )
*
Installing the lock release:
If the lock release is to be fitted to a metal door, use a Ø3.5mm drill bit
and thread the hole made. For wooden doors, use a Ø3mm drill bit.
IMPORTANT:
-
The lock release must be 12Vdc or ac (Golmar).
-
If you wish to connect an AC lock release to one of the outputs, fit the varistor supplied with
the NFC access control module to the lock release terminals to ensure that the module
functions correctly.
WIRING DIAGRAM
( )
*
( )
NFC standalone access control and Golmar AC lock release.
*
The wiring diagram shown below uses a TF-104 transformer (12Vac) to power the module.
( ) 1
Use the varistor supplied if using an AC lock release directly on the terminals of the lock
release.
If connecting two lock releases, use an additional TF-104 transformer.
If you wish to use a safety lock release with inverted functioning (the lock release activates in
the absence of voltage), connect the lock release between C1 and NC1 or C2 and NC2.
TF-104
TF-104
transformer
transformer
PRI
SEC
PRI
SEC
~
~
~
~
~
~
~
~
~ ~
Mains
Mains
( )
For more information, see the TKIT N4502 NFC user manual (code 50123711).
*
https://doc.golmar.es/search/manual/50123711
SW1
P1
3,5 x 25
DIN-7972
M 4 x 8
DIN-963
EL4502/NFC
access control module
PL2
PL1
CN1
NA1
C1
NC1
NA2
C2
NC2
P
-
PL1 PL2
( ) 1
Vac
( ) 1
Vac
4
Nexa NFC standalone
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis .
Golmar reserves the right to make any modifications without prior notice.
Web Code 50123711
golmar@golmar.es
access control
QUICK GUIDE
T
KIT N4502 NFC E
www.golmar.es
Sistemas de comunicación S.A.
N GR