Terminal Blocks - Dedicated Micros drx 300-II Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Facilities/Options cont.:
Video launch amplifier provided with Gain and Lift controls
Camera power outlet provided
Colour-coded outlets: Live, Neutral and Earth
24-volt output option available from factory; plugs into J5 (pre wired)
Telemetry Signals:
(a) Up the coax telemetry signals, designed to operate over 500M of RG59/1Km Ct125 coax; or
(b) Twisted-pair 20mA loop (1200,E,8,1)
Auto-Iris Output:
Returns to original setting 15 seconds after key release. Level programmable from keypad
To drive override input for Cosmicar, or Seiko style lens
Video Input:
v p-p 75R Terminated Input via BNC socket
Video Output:
1v p-p to 4v p-p 75R Impedance via BNC socket
p.c.b. Size:
108 mm Wide x 242 mm Long (without IEC Connector Inserted) x 38 mm High.
p.c.b. Weight:
0.5 kg
Weatherproof Box Size:
190 mm Wide x 380 mm Long x 130 mm High
Boxed Weight:
2.5 kg
P.c.b. Terminal Blocks
The terminal blocks used on the receiver p.c.b. are quick release lever action type and
consequently do not require a screwdriver to make a termination. The correct method of terminating
is as follows:-
1.Use conductors between 0.85 mm
2.Strip the conductor to a length of 5 mm to 6 mm
3.Press down the relevant terminal block lever with a screwdriver or similar tool.
4.Insert the wire.
5.Release the lever.
Removal of a wire is the reverse procedure
drx 300-II Installation Manual
2
and 2.5 mm
2
Page. 4

Publicidad

Tabla de contenido
loading