ENGLISH
GENERAL SPECIFICATIONS
The Klein Tools LAN Explorer™ is a portable voice and data cable tester. It tests and
troubleshoots RJ45, RJ11 and RJ12 terminated cables and patch cords.
• Operating Altitude: 6562 ft. (2000 m)
• Relative Humidity: <90% non-condensing
• Operating Temperature: 14°F to 122°F (-10°C to 50°C)
• Storage Temperature: -4°F to 122°F (-20°C to 50°C)
• Dimensions: 4.9" x 2.5" x 1.3" (12.6 x 6.4 x 3.2 cm)
• Weight: 5.0 oz. (142 g) including batteries and remote
• Battery: 9V
• Maximum non-damaging voltage between pins (RJ Jacks): 66V DC or 55V AC
• Cable Types: Shielded or Unshielded; Cat7, Cat6/6A, Cat5e, Cat3
• Maximum Cable Length: 1000 ft. (305 m)
• Minimum Cable Length (for Split Pair detection): 1.5 ft. (0.5 m)
Specifications subject to change.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
To ensure safe operations, follow these instructions. Failure to observe these warnings
can result in re, electric shock, severe injury or death.
• Read all safety Information before using the product.
• Carefully read all instructions.
• The Lan explorer™ is designed for use on unpowered/dark cable systems.
• Do Not connect Lan explorer™ to live AC power.
• Poorly terminated plugs will damage the jacks on the LAN Explorer. Visually inspect plug
before inserting it into the tester.
• This product is for indoor use only.
• Turn off Lan explorer™ before attempting to replace batteries.
• Do not open the case, other than the battery compartment.
• The battery door must be in place and secure before operating product.
• No user-serviceable parts inside.
• Do NOT expose to open flame, heat sources, equipment that produces heat, or extremes
of environmental temperature.
SYMBOLS ON TESTER
Warning or
Wear approved
Caution
eye protection
WIRING CONDITION INDICATORS
NOTE: See FIG. 1 below for examples of correctly and incorrectly wired connectors.
3
PASS INDICATORS
Will illuminate if the cable is properly wired. For RJ45, the 4 pairs are wired according to the
T568A/568B data cable standards or if cable is wired straight through (i.e., Pin 1 on near
end is wired to Pin 1 on far end; Pin 2 on near end is wired to Pin 2 on far end, etc.).
8
FAULT INDICATORS
MISWIRE: Illuminates if the cable is not wired to one of the cabling standards shown below,
or if the conductor wire order on the near end do not match the conductor wire order on the
opposite end, i.e. if Pin 1 on near end is wired to Pin 2 on the far end.
OPEN: Illuminates if one or more of the conductor wires on the near end are not terminated
properly on the far end, or if any of the near-end contact pins are not properly terminated.
SHORT : Illuminates when two or more conductor wires make contact with each other.
4
SHIELDED INDICATOR
Illuminates when a shielded (ground wire or foil) data cable is properly connected at both ends,
either by ground wire or by foil.
NOTE:
• When "OPEN" and "MISWIRE" exist simultaneously, only can be judged as "OPEN".
• When "SHORT" and "MISWIRE" exist simultaneously, only can be judged as"SHORT"
• When "OPEN" and "SHORT" exist simultaneously for one wire, only can display one status.
If "OPEN" first then "SHORT", judge as "OPEN"; If "SHORT" first then "OPEN", judge as
"SHORT".
• If only one fault ("OPEN" or "SHORT") happens to one wire. For example, wire#1 is open,
wire#4 and wire#5 are shorted, then both "OPEN" and "SHORT" can be detected and displayed.
NOTE: A Cross-Over Wired cable will flash the MISWIRE and PASS LEDs simultaneously. On
an RJ12-terminated wire with pin 1 and 6 open faults, "RJ11 PASS" will be the response.
WARNINGS
CAUTION
NOT insulated - Will
NOT protect against
electric shock
POWERING ON AND OFF / TESTING A CABLE
The LAN Explorer™ has a single button to start a test. When powered off, a short press of
5
the Test button
See INDICATORS section. The results are displayed for 30 seconds before powering off.
If another short press occurs before the 30 second time-out, another test cycle will begin,
followed by another 30 second time-out.
1. Connect one end of the cable under test to the RJ45 port (if testing a data cable) or
RJ11/RJ12 port (if testing a voice cable) located at the top of the main tester body.
2. Connect the other end of the cable under test to the corresponding port on the testing
remote.
3. Press the Test Button
The LAN Explorer™ will automatically power off if there is no test result change for 30 seconds.
To manually power off theLAN Explorer™, press the Test Button
BATTERY REPLACEMENT
When the Low Battery indicator
replaced.
10
1. Loosen screw
2. Remove and recycle exhausted battery.
3. Install new 9V alkaline or carbon zinc battery. Note proper polarity.
4. Replace battery door and fasten securely with screw. Do not over-tighten.
Turn tester off and disconnect any cables. Wipe with a clean, dry lint-free cloth.
Do not use abrasive cleaners or solvents.
Remove the battery when the unit is not in use for a prolonged period of time. Do not
expose to high temperatures or humidity. After a period of storage in extreme conditions
exceeding the limits mentioned in the General Specifications section, allow the unit to
return to normal operating conditions before using.
Read all
instructions
Do not place equipment and its accessories in the trash. Items must be properly
disposed of in accordance with local regulations. Please see www.epa.gov or
www.erecycle.org for additional information.
OPERATING INSTRUCTIONS
causes the LAN Explorer™ to turn on, and a cable test to be executed.
5
to begin the test.
MAINTENANCE
6
blinks or tester does not turn on, the battery must be
9
in battery cover
to access the battery compartment.
CLEANING
STORAGE
WARRANTY
www.kleintools.com/warranty
DISPOSAL / RECYCLE
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street Lincolnshire, IL 60069
1-877-775-5346
customerservice@kleintools.com
www.kleintools.com
5
for 2 seconds.