NEXT PLUS MCW, NEXT PLUS K9-85 MCW
English
Wireless, PowerCode Digital PIR / Pet Tolerant PIR Detectors -
Installation Instructions
Detectores PIR Digital / Inmune a mascotas inalámbricos –
Español
Instrucciones de instalación
Portuguese
Detector PIR Digital / Tolerante animais de companhia Via rádio –
Instruções de Instalação
ENGLISH
1. INTRODUCTION
The NEXT PLUS MCW and NEXT PLUS K9-85 MCW (pet tolerant) are
microprocessor-controlled wireless digital PIR detectors.
NEXT is a registered mark of Visonic Ltd.
The detectors features are as follows:
Combined Fresnel and cylindrical optics improves detection range, up
to 15 meters (40 ft), and false alarm immunity.
NEXT PLUS MCW includes wall creep zone protection.
In NEXT PLUS K9-85 MCW, Target Specific Imaging™ (TSI) technology
is used for distinction between human beings and pets weighing up to 38
kg (85lb).
Incorporates a fully supervised PowerCode transmitter.
The advanced True Motion Recognition™ algorithm (patented) allows
distinguishing between the true motion of an intruder and any other
disturbances which may cause false alarms.
Sophisticated frequency domain digital signal processing.
No vertical adjustment is needed.
An on-board motion event jumper determines whether 1 or 2
consecutive motion events trigger an alarm.
Automatic termination of walk-test after 15 minutes.
After detection, the detector disarms itself to save battery power. It
rearms (reverts to the ready state) if there is no subsequent detection
throughout the following 2-minute period.
An optional version provides better protection for systems compliant
with DD243. After initial detection, the detector is capable of 7
additional detections for a period of 5 minutes.
Further detection is possible only if no movement occurs during the
following 2 minutes. The detector will revert to the initial state if there is
no movement for an additional 5 minutes.
Microprocessor-controlled temperature compensation.
Sealed chamber protects the optical system.
Front cover tamper switch. Option - Back tamper switch – NEXT PLUS
T MCW.
White light protection.
Note: NEXT PLUS T MCW: "T" stands for rear tamper detector variant.
For UL installations: The detector is for use with UL listed control unit
PowerMax+ only. Pet tolerance has not been evaluated by UL.
2. SPECIFICATIONS
Detector Type: Dual element low-noise pyroelectric sensor.
Lens Data
No. of Curtain Beams / curtains:
NEXT PLUS MCW: 18 far, 18 mid, 10 close.
NEXT PLUS K9-85 MCW: 18 far, 18 mid, 18 close.
Max. Coverage: 15 x 15 m,
Pet Tolerance (NEXT PLUS K9-85 MCW Only): Up to 38 kg (85 lb).
ELECTRICAL
Internal Battery: 3V Lithium battery, type CR-123A. For UL installations,
use Panasonic or Sanyo only.
Nominal Battery Capacity: 1450 mA/h.
Standby Current Drain: Approx. 0.025 mA.
Transmit Current Drain: 20 mA (including LED).
Low Battery Threshold: 2.7V
Battery Life (with LED on): Typically over 3 years.
Battery Power Test: Performed immediately upon battery insertion and
periodically after every several hours.
FUNCTIONAL
True Motion Event Verification: 2 position selector - 1 (OFF) or 2 (ON)
motion events.
Alarm Period: 3 seconds.
Visual Indications:
LED Lights for about 3 seconds upon transmission of alarm & tamper
messages and upon motion detection in the walk test mode.
LED Flashes during the power-up stabilization period, or after
restoring (pressing) the tamper switch.
LED Does not light upon transmission of supervision messages.
D-300058 NEXT PLUS MCW, NEXT PLUS K9-85 MCW
(49 x 49 ft) / 90°
Fig. 1 - NEXT PLUS MCW / NEXT PLUS K9-
Rearm Timer: Rearms the detector 2 minutes after the last alarm. Timer
disabled in the walk test mode – not applicable for the DD243 version (see
section 1).
WIRELESS
Frequency (MHz): 315 (U.S. version), 433.92, 868.95, 869.2625 or other
frequency according to local requirements.
Transmission Sequence: 3 data bursts at variable intervals within 3 sec.
Encoding: 24-bit ID, over 16 million possible combinations.
Total Message Length: 36 bits.
Tamper Alert: Reported when a tamper event occurs and in any
subsequent message, until the tamper switch is restored.
Supervision Message: Signaling at 60 minutes interval (U.S. version), 15
minute interval (UK version) or according to local standards.
MOUNTING
Height: 1.8 - 2.4 m (6 - 8 ft). For NEXT PLUS K9-85 MCW, the
recommended height is up to 2.1 m (7 ft)
Installation Options: Surface or corner.
ACCESSORIES:
BR-1: Surface mounted swivel bracket, adjustable 30° down and 45°
left/45° right.
BR-2: BR-1 with a corner adapter
BR-3: BR-1 with a ceiling adapter
ENVIRONMENTAL
RFI Protection: >20 V/m up to 2000 MHz.
°
Operating Temperatures: -10
C to 50
°
Storage Temperatures: -20
C to 60
Compliance with Standards: Designed to meet FCC Part 15 and
Directive 1999/5/EC of the European Parliament. En 50131-1, EN 50131-
2-2, EN 50131-6, Type C Grade 2 (detector with back tamper switch) /
Grade 1 (detector without back tamper switch), Class II.
PHYSICAL
Size (H x W x D): 94.5 x 63.5 x 53.0 mm (3-11/16 x 2-1/2 x 2-1/16").
Weight (with battery): 70 g (2.5 oz).
Color: White.
PATENTS: U.S. Patents 5,693,943 6,211,522 D445,709 (another
patent pending).
3. INSTALLATION
3.1 General Guidance
1. Keep away from heat
sources.
2. Do not expose to air drafts.
3. Do not install outdoors.
4. Avoid direct sunshine.
Important! The K9-85 detector is immune to 38 kg (85 lb)
animals moving on the floor or climbing on furniture as long as
the activity takes place below 1 m (3 ft). Above the 1 m (3 ft)
height limit, the detector is immune to 19 kg (42 lb) pets, but
the pet tolerance will decrease as the pet gets closer to the
detector. It is therefore recommended to select a mounting
location that minimizes potential close proximity of animals.
3.2 Installation Procedure
1. Mounting - see fig. 4.
2. Battery installation (see fig. 4 and the note below)
3. Detector reset:
With the battery in place, press both tamper switches simultaneously
(see fig. 4) and release them. The front LED will flash for about 2
minutes until the detector stabilizes.
Note: The detector transmits a low battery signal upon detection of low
voltage. It is recommended to wait about 1 minute after battery
removal, before inserting the new battery.
4. Enrolling:
Enroll the detector's ID into the alarm system memory according to the
alarm system installation instructions. When you are instructed to
transmit, press both tamper switches again and release them. You may
enroll the detector's ID while the detector's LED flashes.
5. Jumpers settings - see fig. 5.
GB/US: Walk-Test LED
SP: LED de modo de pruebas
PT: LED do teste de passagem
GB/US: Lens
SP: Lente
PT: Lente
85 MCW
°
°
°
C (14
F to 122
F).
°
°
°
C (-4
F to 140
F).
(see fig. 3)
5. Keep wiring away from power
cables.
6. Do not install behind partitions.
7. Mount on solid stable surface.
1