6.2. – ADJUST OF THE ARMS
Check the adjustment of the round joints, both
of the rocker arm and the fork and the dome. If
it is necessary, proceed to adjust them: they
must move effortlessly and stay in position.
Excessive tightening of them may produce a
blockage of the movement. Adjust by screws
nº 18,19, 20 or 21.
6.3. - CHANGE THE FUSES
If the switch is "on" and the lamp is connected to the mains but does not work, then check the fuse following these instructions:
1. Remove the embellisher nº 9.
2. Unscrew the fuse box using a screwdriver and replace the fuse. (250VF2A). Check on ceiling plate.
3. Install embellisher.
7. - TECHNICAL CHARACTERISTICS
Electrical connection
Luminous intensity at 100 cm
Illumination intensity adjustment
Light source
Colour temperature
CRI
Power
Ø Light head
Field diameter d
10
Field diameter d
50
Depth of field (L1 + L2)
Colour
Approximate lamp Weight
8. - PLANS AND DRAWINGS
See page 10 & 11
Fig. 4a – Arm adjustment.
100-240V / 47-63Hz
65.000 lux (± 10%)
from 20.000 to 65.000 lux
LED
4.500 K (±5%)
>95
MODELS:
28W
300 mm
260 mm
130 mm
170 cm (80 + 90cm)
RAL 9002
19.5 Kg
IG-65M
Moveable lamp
IG-65W
Wall mount lamp
IG-65C
Ceiling lamp
IG-65DC Ceiling lamp with double arm
IG-65MB Moveable lamp with battery equipment
170 cm
Fig. 5 – General dimensions
Fig. 4b – Cupola and fork adjustment.
Página 9 de 11