4.2. Operation
When the running speed of the generating set has stabilised (approximately 3 minutes):
Check that the circuit breakers (fig A – No.6) are well depressed Press if necessary.
Connect the devices to be used to the electrical sockets (fig. A – No. 7) of the generating set.
4.3. Switching off
Stop & disconnect the devices from the electrical sockets (fig. A – No.7).
Allow the engine to run idle for 1 or 2 min.
Activate the stop lever: The generating set shuts down.
Always ensure suitable ventilation for the generating set.
Even after shut down, the engine continues to give off heat.
Warning
5. Safety features
5.1. Circuit breaker
The set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the event of an
overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.
6. Maintenance schedule
6.1. Reminder of use
The maintenance operations to be carried out are described in the maintenance schedule. The interval for this is supplied as a guide
and for generating sets operating with fuel and oil which conform to the specifications given in this manual.
If the generating set is used under extreme conditions, the interval between the maintenance operations must be shortened.
6.2. Maintenance table
Operations to be
carried out when
Component
the 1
Fastenings
Check the level
Engine oil
Oil filter
Fuel filter
Air filter
Generating set
Valves *
Fuel tank & pipes*
Spark arrester
* Operation(s) to be entrusted to one of our agents.
In case of use in dusty areas, clean the air filter more frequently.
In case of limited use, drain the oil every year at the latest.
Each time
st
due date is
it is used
attained
•
Check
•
Change
Replace
Replace
•
Check
Clean
Clean
Check*
Clean*
Clean*
After
st
1
month
Every
or
1 month
Every 10 hours
•
After
Every
2 months
6 months
or
or
Every 50
Every 250
hours
hours
•
•
•
•
Every
1 year
or
Every 500
hours
•
•
•
•*
•*
•*