Use the appropriate 1 inch electrical clamp (not supplied) and 1 – 1 ½ inch
5.
electrical washer (not supplied) installed in the Units Electrical cable access
hole. Then pass the appropriate sized electrical cable through the clamp
and tighten.
Connect the wires from circuit to the terminal block;for TC10 and TC10Y
6.
connect to L1, L2 terminals for TB03X connect to L and N terminals. Tighten
screws.
WARNING:If not installed correctly, electrical control system will be
damaged and warranty will be voided.
Connect the ground wires to the terminal block connection labeled
7.
G.Tighten screws.
Ensure ground service wire from the G terminal of the unit is connected to
8.
the grounding block in the electrical panel.
CAUTION: CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A
9.
GROUND FAULT CIRCUIT INTERRUPTER.
USE COPPER CONDUCTORS ONLY.
CANADA: USE BONDING CONDUCTOR IN ACCORDANCE WITH THE
CANADIAN ELECTRICAL CODE, PART I. A green terminal (or a wire
connector marked "G", "GR", "GROUND", or "GROUNDING") is provided
with the control box. To reduce the risk of electric shock, connect this
terminal or connector to the grounding terminal of the electric service or
supply panel with a continuous copper wire in accordance with the
Canadian Electrical Code, Part I.
Ground wire from
output water pipe to
metal plate.
Figure 6: Internal Diagram
Metal plate with 2 grounding wire
connected. One to water pipes and
the other to ground
terminal.Terminal:Wire from power
supply to G.
Ground wire
connecting incoming
and output water pipes
10