American Hometec AHQ-TC10 Manual De Instalación Y Funcionamiento página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Model AHQ-TC10 Electric Tankless Heater
Application
Power setting selection
Power setting 240V
Rated voltage
Max Current load 240V
Breaker required
Wire size required
Model ACQ-TC10Y Electric Tankless Heater
Application
Power setting selection
Power setting
Rated voltage
Max Current load
Breaker required
Wire size required
Application
Power setting
selection
Power setting
Rated voltage
Max Current load
Breaker required
Wire size required
One sink with regular
flow rate or up to three
sinks with low flow
faucets of 0.5 GPM
Setting 1
9.5 kW
240 V60 Hz (Suitable for 208V to 240V)
39.6 A
40 A
8 AWG
One sink with regular
flow rate or up to three
sinks with low flow
faucets of 0.5 GPM
Setting 1
9.5 kW
34.3 A
40 A
8 AWG
Model ACQ-TB03X Electric Tankless Heater
One sink with low
flow rate faucets
One sink with
regular flow
rate in warm
area
Setting 2
7.2kW
30 A
30 A
10 AWG
One sink with
regular flow
rate in warm
area
Setting 2
8.3 kW
277 V
60 Hz
30 A
30 A
10 AWG
One sink with low
flow rate faucets
Setting 1
3.4 kW
120 V
60 Hz
28.3 A
30 A
10 AWG
8
One sink with low
flow faucets
Setting 3
4.8 kW
20 A
20A
12 AWG
One sink with low
flow faucets
Setting 3
5.5 kW
19.9 A
20A
12 AWG
Setting 2
2.4 kW
20 A
20A
12 AWG

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Acq-tc10yAcq-tb03x

Tabla de contenido