Cadet BTF Serie Instrucciones Para La Instalación página 3

Ocultar thumbs Ver también para BTF Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Model BTF2 – 120 Volt Application
A. Connect the red thermostat
wire labeled L2 to the black
thermostat wire labeled OFF
as shown.
MULTIPLE HEATER WIRING - OPTIONAL
More than one baseboard heater can be wired in parallel on same circuit (be sure to check national and local codes for safety requirements).
Additional wire is required. Important: When wiring multiple heaters to one thermostat, the baseboards must be in the same room.
Maximum amperage rating: 22 amps.
BTF1
1. Disconnect one factory connector on each baseboard.
2. Connect one supply lead to the red thermostat wire.
3. Connect black thermostat wire to one wire on each heater.
4. Connect remaining wire from each heater to the remaining supply lead.
5. Connect supply ground wire to both ground screws.
IMPORTANT: Wires shown in illustration are for reference only. All electrical
work and materials must comply with the National Electric Code (NEC) and
all state and local codes.
NOTE: Field wiring is not provided.
BTF2
1. Disconnect one factory connector on each baseboard.
2. Connect one supply wire to each red thermostat wire.
3. Connect one black thermostat wire to one wire from each heater.
4. Connect remaining black thermostat wire to the remaining wire from each heater.
5. Connect supply ground wire to both ground screws.
IMPORTANT: Wires shown in illustration are for reference only. All electrical
work and materials must comply with the National Electric Code (NEC) and all
state and local codes.
NOTE: Field wiring is not provided.
InSTallaTIon InSTrucTIonS
GROUND
SCREW
B. Connect the neutral supply
wire to one of the heater wires.
BTF WIRING INSTRUCTIONS CONCLUSION - PART 3
STEP 6
Carefully tuck all wires into wiring compartment
and attach the thermostat to the baseboard heater.
InSTallaTIon InSTrucTIonS
GROUND
SCREW
C. Connect the supply hot
wire to the remaining red
thermostat wire.
GROUND
SCREW
FIELD WIRING
GROUND
SCREW
GROUND
SCREW
D. Connect the remaining black thermostat
wire to the remaining heater wire.
PROCEED TO PART 3
FIELD WIRING
FIELD WIRING
NOT PROVIDED
FIELD WIRING
NOT PROVIDED
FIELD WIRING
NOT PROVIDED
FIELD
WIRING
NOT
PROVIDED
GROUND
SCREW
GROUND
SCREW

Publicidad