1. CAUTIONS
Before installing this water heater,check and confirm that the earthing
on the supply socket is reliably grounded.
can not be installed and used. Do not use extension boards. Incorrect installation and use of this
electrical water heater may result in serious injuries and loss of property.
Special Cautions
The water heater is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instructions concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the heater.
The wall in which the electrical water heater is installed must be able
to bear the load more than two times of the heater filled fully with
water without distortion and cracks.
be adopted.
The supply socket must be earthed reliably. The installation height of the
supply socket must not be lower than 1.8m. The rated current of the
socket must not be lower than 16A. The socket and plug must be kept
dry to prevent electrical leakage. If the flexible power supply cord is
damaged, the special supply cord provided by the manufacturer must
be selected, and replaced by the professional maintenance personnel.
The maximum inlet water pressure is 0.5MPa; the minimum inlet water pressure is 0.1MPa, if this
is necessary for the correct operation of the appliance.
When using the heater for the first time (or the first use after maintenance), the heater can not be
switched on until it has been filled fully with water. When filling the water, at least one of the outlet
valves at the outlet of the heater must be opened to exhaust the air. This valve can be closed after
the heater has been filled fully with water.
The pressure relief valve attached with the heater must be installed
at the cold water inlet of this heater, and make sure it is not exposed
in the foggy.
open wide in the air. In order to drain away the water inside the inner container, it can be drained
away from the pressure release valve. Twist the thread screw of the pressure release valve off, and
lift the drain handle upwards(See Fig.1) . The drainage pipe connected to the pressure release
hole must be kept sloping downwards and in a frost-free environment. The water may drip from the
discharge pipe of the pressure-relief device and that this pipe must be left open to the atmosphere.
During heating, there may be drops of water dripping from the pressure release hole of the
pressure relief valve, this is a normal phenomenon.
not be blocked under no circumstances, otherwise, the heater may
get damaged, even resulting in accidents. If there is a large amount
of water leak, please contact customer care center for repair.
The pressure relief valve need to be checked and cleaned regularly, so as to make sure it will not
be blocked.
The water may be outflowed from pressure relief valve, so the outflow pipe must
Otherwise, the electrical water heater
Otherwise, other strengthening measures must
The pressure release hole shall
2