Hardware Version = 0.01
MAC Address = 00:1e:c9:b2:c7:1f
Common settings:
Register DNS RAC Name = 0
DNS RAC Name = iDRAC6
Current DNS Domain =
Domain Name from DHCP = 0
IPv4 settings:
Enabled = 1
Current IP Address = 192.168.0.120
Current IP Gateway = 192.168.0.1
Current IP Netmask = 255.255.255.0
DHCP Enabled = 0
Current DNS Server 1 = 0.0.0.0
Current DNS Server 2 = 0.0.0.0
DNS Servers from DHCP = 0
IPv6 settings:
Enabled = 0
Current IP Address 1 = 2002:0000:0000::0001
Current IP Gateway = ::
Prefix Length = 64
Autoconfig = 1
DNS Server from DHCPv6 = 0
Current DNS Server 1 = ::
Current DNS Server 2 = ::
System Information:
System Model = PowerEdge R610
System BIOS Version = 0.2.4
BMC Firmware Version = 0.32
Service Tag = AC056
Host Name =
OS Name =
Power Status = ON
Watchdog Information:
Recovery Action = None
Present countdown value = 15 seconds
Initial countdown value = 15 seconds
Ejemplos
racadm getsysinfo -A -s
l
"System Information:" "PowerEdge 2900" "A08" "1.0" "EF23VQ-0023" "Hostname"
"Microsoft Windows 2000 version 5.0, Build Number 2195, Service Pack 2" "ON"
racadm getsysinfo -w -s
l
System Information:
System Model = PowerEdge 2900
System BIOS Version = 0.2.3
BMC Firmware Version = 0.17
Service Tag = 48192
Host Name = racdev103
OS Name = Microsoft Windows Server 2003
Power Status = OFF
Watchdog Information:
Recovery Action = None
Present countdown value = 0 seconds
Initial countdown value = 0 seconds
Restricciones
Los campos Nombre de host y Nombre del sistema operativo en el mensaje de salida de getsysinfo mostrarán información correcta sólo si el software de
sistemas Dell™ OpenManage™ está instalado en el sistema administrado. Si OpenManage no está instalado en el sistema administrado, es posible que estos
campos estén vacíos o tengan información incorrecta..
getractime
NOTA:
Para usar este comando, se debe tener permiso para Iniciar sesión en el iDRAC.
La
Tabla A-16
describe el subcomando getractime.