500 mPas) from a maximum suction depth of 5 m.
`
`
The instrument is suitable for sampling liquids from
0 - 40 °C.
`
`
For chemically demanding applications use pump
hose made of Marprene (beige, durable), for food
applications use pump hose made of silicone
(transparent).
`
`
The instrument is only suitable to take samples and
not for continuous operation.
`
`
The instrument is suitable for filling open sampling
bottles.
`
`
Only use the instrument with the recommended
sample bottles specified in the accessories.
`
`
Protect the instrument against effects of weather
exposure during storage.
Parts in contact with medium
`
`
PE (Suction hose)
`
`
PP (Hose connector)
`
`
Marprene or silicone (Pump hose)
`
`
LDPE (Sample bottle)
Scope of delivery
2 x
Pump hose (1x Marprene, 30 cm;
1 x Silicone 30 cm)
1 x
Pump head
1 x
Suction hose , PE, 5 m
1 x
Hose connector, PP
1 x
Bottle basket
1 x
Sample bottle, LDPE, 250 ml
1 x
Bosch drive unit
2 x
Rechargeable battery
1 x
Battery charger
`
`
Check delivery for completeness and transport damage.
`
`
Point out any damage in the packaging to the
freight forwarder/supplier immediately.
Assembly
1. Insert the pump hose  into the pump head .
2. Cut the suction hose  off to the required length and
attach it to the pump hose  with the hose connector .
3. Fix the bottle basket  in place with the tightener .
CAUTION!
The mounting bracket may break.
`
`
Do not load the suspension too heavily (max. 2 kg).
`
`
Check the bottle basket to ensure it is properly
seated. Allow the end of the holding rod to
protrude out about 5 cm upward.
`
`
Wear appropriate protective clothing.
4. Place the sample bottle  in the bottle basket .
5. Insert the pump hose  about 1 - 3 cm into the
sample bottle .
NOTE!
Allow the pump hose to protrude loosely into the
sample bottle.
CAUTION!
Bursting of hoses and hose connectors due to wear
or chemical stress.
`
`
Carry out a visual inspection every time before using.
6. Place the pump attachment  in the holder  of
the Bosch drive unit . Turn the locking ring
the direction
NOTE!
Follow the safety instructions for the Bosch drive
unit and pump head.
Safe sampling
CAUTION!
Possibility of electrical shock.
14
`
`
Follow the instructions of the drive manufactu-
15
rer/battery charger manufacturer.
1. Set the gear selector switch
speed range).
2. Lower the suction hose  into the sample liquid.
3. Press the On/Off switch
CAUTION!
Risk of atomisation. Ingress of liquids in the instrument.
`
`
In case of uncontrolled escape of hazardous
liquid, interrupt the sampling immediately and
remove the Bosch drive unit.
`
`
Contact the dealer or manufacturer.