Pfister LG15 Serie Manual Del Usuario página 2

Ducha de mano para tina redonda con mecanismo de desvío
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Thank you for purchasing this Pfister product. All Pfister products are
carefully engineered, and factory tested to provide long trouble-free use
under normal conditions. This product is easy to install using basic tools
and our easy to follow illustrated instructions. If you have any questions
regarding this product, call 1-800-Pfaucet (1-800-732-8238).
1 BEFORE PROCEEDING
WARNING: Read all the instructions completely before proceeding.
Pfister recommends calling a professional if you are uncertain about
installing this product!
This product has been designed for use with the Pfister 0X6-140R
or JX6-140R Roman Tub series rough-in. It will not work with any other
product.
This product should be installed in accordance with all local and state plumbing
and building codes. For optimum performance of your new Pfister faucet, a
minimum water pressure of 25 PSI (172 kPa) is recommended.
Your installation will require supply tubes. To preserve the high flow
characteristics of these valves, it is necessary to use ½" I.D. (⅝" O.D.) copper
tubing or Pfister Quick Connect Hose Kit 15-136. Consult the store where
you purchased your faucet for the recommended connections that you may
require for your area. Before installing your Diverter Valve, Pfister recommends
installation of a ½" shock arrester before each supply valve. If deck thickness
exceeds 1-¾" Pfister Stem Extension Kit 974-370 must be used.
2 SHUT OFF WATER SUPPLY
Locate water supply inlets and shut off the water supply valves. These are
usually found near the water meter. If you are replacing an existing faucet,
remove the faucet from the tub and clean the tub surface thoroughly.
3
3 TOOLS RECOMMENDED:
For Iron Pipe Installation:
● PTFE Plumber's Tape
● Slotted screwdriver
● Adjustable wrench
● Pipe Wrench
● Cloth
For soldered copper and non-standared installations, some additional tools
may be required.
4
1-1/4" (32 mm) DIA.
1-3/4" (45 mm) MAX.
4 RECOMENDED COMPONENT LOCATIONS
Maximum distance between Diverter Valve (4A) and Spray Head Holder (4B)
is not to exceed 16" (406 mm). Note: Recommended all holes to be 1-¼"
(32 mm) diameter.
● Phillips Screwdriver
● Flashlight
16" (406 mm) MAX.
4A
4B
ENGLISH
5
5H
5 DIVERTER VALVE INSTALLATION
Remove upper Locknut (5A) and Washer (5B) from Diverter Valve Body (5C).
From underneath deck, insert Diverter Valve Body (5C) through deck hole
(5D) and adjust lower Locknut (5E) and Washer (5F) so that top of Diverter
Shank (5G) is ½" (13 mm) above Mounting Surface (5H). From above deck,
place Locknut (5A) and Washer (5B) onto Diverter Shank (5G) and wrench
tighten until Diverter Valve Body (5C) is firmly secured to deck.
6
6 SPRAY BASE HOLDER INSTALLATION
Connect Spray Holder (6A) onto Spray Base (6B). Insert Spray Base (6B)
trough Washer (6C) and into Deck Hole (6D). From underneath deck, place
Washer (6E) onto Spray Base Shank (6F) and tighten with Locknut (6G). Be
sure Spray Holder (6A) is centered and facing forward before final tightening.
2
5A
5G
1/2" (13 mm)
5C
6A
6F
6E
6G
5B
5D
5F
5E
6B
6C
6D

Publicidad

Tabla de contenido
loading

Tabla de contenido