7
7C
7 SPRAY HOSE INSTALLATION
From above deck, insert Decorative Hose (7A) through Spray Base Holder
(7B). From underneath deck, connect one end of Service Hose (7C) to Diverter
Outlet (7D).
Do not let Decorative Hose (7A) retract down into Spray Base Holder
(7B).
8
8A
8 SPRAY HOSE CONNECTIONS
Attach Service Hose (8A) to the end of Decorative Hose (8B).
7A
7B
7D
8B
ENGLISH
9
9C
9 DIVERTER VALVE & SPOUT ADAPTER CONNECTION
Connect Diverter Tub Outlet (9A) to Spout Adapter (9B). Use either Pfister
15-136 Pipe Connect Kit (Supplied Separately) (½"-14 NPSM thread) (9C) or
solder ½" (13 mm) I.D. (⅝" (16 mm) O.D.) copper lines (cut to length).
For threaded fittings, wrench tighten and use PTFE Plumber's tape per
manufacturer's instructions.
When using copper tubing, remove all internal parts from components
prior to soldering. Failure to do so can result in water damage.
10
10B
10 DIVERTER VALVE & HANDLE VALVE CONNECTIONS
Connect Diverter Inlets (10A) to Handle Valve Outlets (10B). Use either Pfister
15-136 Pipe Connect Kit (Supplied Separately) (½"-14 NPSM thread) or solder
½" (13 mm) I.D. (⅝" (16 mm) O.D.) copper lines (cut to length).
For threaded fittings, wrench tighten and use PTFE Plumber's tape per
manufacturer's instructions.
When using copper tubing, remove all internal parts from components
prior to soldering. Failure to do so can result in water damage.
Be sure all pipes are securely fastened to construction to prevent vibration.
3
9A
9B
10B
10A
10A