4. FAULT INDICATIONS
For safety and protection purposes, EWM1 will
instantly power down/prevent from powering up
the electrical appliance plugged into EWM1 outlet
when the following faults are present:
• OVERVOLTAGE – voltage has increased
above 260VAC.
• UNDERVOLTAGE – voltage has dropped be-
low 190VAC.
• OVERCURRENT – current has increased
above 12,5A.
• RELAY FAULT – unable to power up the appli-
ance due to faulty relay.
• TEMP. FAULT – the environmental temper-
ature has dropped below -35°C (-31°F) or in-
creased above +90°C (+194°F).
In addition, the user can view the existing faults
by EKB2 key pad (only for ESIM364) or by access-
ing the ELDES Cloud Services account. In order to
clear the existing faults, please press the
ton on EWM1, turn OFF the electrical appliance or