Tools Required: (2) 7/16" socket or box wrenches.
To position the handle at operating height:
Step 1: Remove and keep the hardware securing the
handle to the legs.
Step 2: Raise handle until holes align with the upper
holes in the legs.
Step 3: Re-insert hardware as shown,
securely.
THE PROPER SIZE SO- type feeder cable MUST BE USED for the electrical hook-up of this heater. The proper cable size is shown
in the tables below (A.W.G./ # of conductors.) Table 1 is for cable 50ft. in length or less. Table 2 is for cable longer than 50ft.
A 25ft. cable kit can be purchased from the
factory. Refer to the kit part numbers in table at
right.
CABLE KITS INCLUDE:
•
25 feet of Type SO cable, with either 3-
conductors or 4-conductors, depending on
the heater requirements.
To order cable kits
Phone: 1-800-495-4525
•
Feeder cable or cable kit assembly MUST BE
made by licensed electricians ONLY.
•
Service panel or receptacle used to supply power
to these heaters MUST have a ground bus or
ground pole that is securely bonded to earth
ground.
•
Connect green ground conductor on feeder cable
or cable kit to grounding lug on heaters.
•
Comply with ALL local electrical codes and the
National Electric Code (NFPA70) when providing
electrical power to these heaters.
Issue Date: 4-19-02 Rev. Date: 03/14
FES – SERIES ASSEMBLY
and fasten
WIRING
Model
Table 1
FES1520-3A
15kW, 208 Volt, 3-Ph
FES1524-1A
15kW, 240 Volt, 1-Ph
FES1524-3E
15kW, 240 Volt, 3-Ph
FES1548-3E
15kW, 480 Volt, 3-Ph
FES1560-3A
15kW, 600 Volt, 3-Ph
FES3048-3A
30kW, 480 Volt, 3-Ph
FES3060-3A
30kW, 600 Volt, 3-Ph
Model
Table 2
FES1520-3A
15kW, 208 Volt, 3-Ph
FES1524-1A
15kW, 240 Volt, 1-Ph
FES1524-3E
15kW, 240 Volt, 3-Ph
FES1548-3E
15kW, 480 Volt, 3-Ph
FES1560-3A
15kW, 600 Volt, 3-Ph
FES3048-3A
30kW, 480 Volt, 3-Ph
FES3060-3A
30kW, 600 Volt, 3-Ph
Rev. Level: 19
ECO1-6931
Bolts
Washers
Washers
Unit Rating
Cable Size - Under
50ft. long
6/4
4/3
6/4
12/4
12/4
6/4
6/4
Unit Rating
Cable Size – Over
50ft. long
12/4
12/4
ELECTRICAL SHOCK HAZARD
FIRE HAZARD
RISQUE DE CHOC ÉLECTRIQUE
RISQUE D'INCENDIE
Serious injury or death may occur
Blessures graves ou la mort peuvent survenir.
Disconnect from electrical supply before installing
feeder cable to these heaters.
Couper l'alimentation électrique avant d'installer un
câble d'alimentation de ces appareils de chauffage.
Read and follow all safety information in box to
the left.
Lire et suivre toutes les consignes de sécurité
dans la boîte vers la gauche.
OIPM P/N 8997
Nuts
Cable
Kit Number
03164001
08805300
03164001
03164201
03164201
03164001
03164001
Max. Cable
Length (ft)
4/4
120
2/3
215
6/4
150
140
190
6/4
300
6/4
350
Page 5 of 27