Tripp Lite Network Dataline Surge Suppressors are designed to protect data and communications
equipment against AC transients caused by lightning, electrostatic discharge and ground surges that
can enter equipment from the signal lines or chassis ground.
Tripp Lite Network Dataline Surge Suppressors described here protect virtually any pieces of net-
worked equipment using 100Base-T, 10Base-T, 10Base-2 and 10Base-5 Ethernet, Token Ring, RS232,
RS422/423/485, parallel, dial-up modems, fax, ISDN, DDS, T-1 and most other communication in-
terfaces.
Installation
1. Make sure the computer, network device or other equipment is logged OFF the network (if appli-
cable). Turn OFF power to the equipment.
2. Disconnect the cable from the equipment to be protected.
3. Connect the Tripp Lite Network Dataline Surge Suppressor directly to the equipment. DB9 and
DB25 models are reversible, to work with male or female ports. To change gender, remove the thumb-
screws, reverse their direction and reinstall.
4. Attach the green ground wire on the surge suppressor directly to the protected equipment's chas-
sis. (Except DB9, DB15 and DB25 models.)
5. Reconnect the cable to the Tripp Lite Network Dataline Surge Suppressor.
The Tripp Lite Network Dataline Surge Suppressor must be properly grounded and positioned as
close as possible to the equipment to be protected. For best results, it is required that the length of the
signal line and ground wire (if equipped) between the surge suppressor and the protected equip-
ment be kept as short as possible, not to exceed 12 inches (12"). It is best to install the surge suppres-
sor directly to the equipment, as noted above.
Installing a typical Tripp Lite Network Dataline Surge Suppressor is equivalent to adding approxi-
mately three feet (3') of typical data communication cable to a segment.
The Tripp Lite Network Dataline Surge Suppressor does not protect the equipment on the opposite
end of the cable. Normally, protection at both ends is recommended.
When properly installed, the Tripp Lite Network Dataline Surge Suppressor will only protect
against surges on the dataline portion of your installation. Simultaneous AC surge suppres-
sion/power protection in the form of an ISOBAR
is strongly recommended for complete system/network protection and can also extend Ulti-
mate Lifetime Insurance coverage to connected equipment.
Network Dataline
Surge Suppressors
Español: p. 5
Français: p. 9
NOTE!
NOTE!
CAUTION!
CAUTION!
®
surge suppressor or Tripp Lite UPS system
1

Publicidad

loading

Resumen de contenidos para Tripp-Lite DHUB

  • Página 1 Network Dataline Surge Suppressors 1111 W. 35th Street Español: p. 5 Chicago, IL 60609 USA Customer Service: (773) 869-1234 Français: p. 9 www.tripplite.com Tripp Lite Network Dataline Surge Suppressors are designed to protect data and communications equipment against AC transients caused by lightning, electrostatic discharge and ground surges that can enter equipment from the signal lines or chassis ground.
  • Página 3 All surge suppressors listed have component response times of less than 1 picosecond. Nominal Peak Pulse Model: Description: Clamping Voltage: Current: DHUB DHUB-18V DHUB: RJ45, 8-port ethernet, token ring 7.5 volts, protecting 750 amps RS422/423/485, AS400/ wires 1-8 on all ports. Sys3x protector for hubs, repeaters, terminal servers, MUXs, MAUs, etc.*...
  • Página 4 Nominal Peak Pulse Model: Description: Clamping Voltage: Current: Serial DB25 RS-232 DB25 protector (wires 1-8, DB25-ALL 20) for male or female ports of data terminal & computing 18 volts, protecting equipment. DB25-ALL: 340 amps pins 1-8, 20 and chas- Serial DB25 RS-232 protector (pins 1-25) sis.
  • Página 5 LIFETIME LIMITED WARRANTY Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and workmanship for its lifetime. If the product should prove defective in material or workmanship within that period, Seller will repair or replace the product, in its sole discretion.
  • Página 6: Instalación

    Supresores de Sobretensiones Transitorias 1111 W. 35th Street Para Líneas de Datos Chicago, IL 60609 USA Servicio a Clientes: (773) 869-1234 de Redes www.tripplite.com Los Supresores Tripp Lite de Sobretensiones Transitorias para Líneas de Datos de Redes han sido diseñados para proteger datos y equipos de comunicaciones contra sobretensiones de CA causadas por rayos eléctricos, descargas electrostáticas y sobretensiones en la conexión a tierra que pueden introducirse a los equipos por medio de las líneas de comunicación o el chasis.
  • Página 7: Especificaciones

    1 picosegundo. Voltaje Nominal Cresta de Modelo: de Fijación Corriente: Descripción: Impulsos: DHUB DHUB: protector tipo RJ45, DHUB-18V 7.5 voltios, protector ethernet de 8 puertos, token 750 amperios para alambres 1-8 en ring RS422/423/485, todos los puertos.
  • Página 8 Voltaje Nominal Cresta de Modelo: Descripción: de Fijación Corriente: Impulsos: Protector para puertos DB25 seriales DB25 RS232 DB25-ALL (alambres 1-8, 20) tipo macho o hembra para terminales de datos y equipos de computación 18 voltios con incluso computadoras protección para las 340 amperios personales, impresoras, clavijas o pines 1-8,...
  • Página 9 GARANTIA VITALICIA LIMITADA El Vendedor garantiza que este producto, si es usado de acuerdo con todas las instrucciones provistas, estará libre de defectos originales en materiales y mano de obra por un período de dos años a partir de la fecha inicial de compra. Si este producto presentara defectos en materiales o mano de obra dentro del período antes mencionado, el Vendedor lo reparará...
  • Página 10 Suppresseurs de Surtensions pour la Ligne de 1111 W. 35th Street Chicago, IL 60609 USA Assistance Client: (773) 869-1234 Données de Réseau www.tripplite.com Les Suppresseurs de Surtensions pour la Ligne de Données de Réseau de Tripp Lite sont conçus pour protéger le matériel de données et de transmissions contre les coupures de courant C.A.
  • Página 11 1 picoseconde. Tension de Retenue Courant Maximal Modèle: Description: Nominale: d’Impulsion: DHUB DHUB: Protecteur RJ45, Ethernet 8-port, Token Ring DHUB-18V RS422/423/485, AS400/ 7.5 volts, protégeant Sys3x pour hubs, répéteurs, les câbles 1-8 sur tous 750 ampères serveurs terminaux, MUX les ports.
  • Página 12 Tension de Retenue Courant Maximal Modèle: Description: Nominale: d’Impulsion: Protecteur séquentiel DB25 DB25 RS232 (câbles 1-8, DB25-ALL 20) pour ports mâle ou femelle de terminal de données et de matériel informatique comprenant 18 volts, protégeant 340 ampères des ordinateurs, des la borne 1-8, 20 et imprimantes, des châssis.
  • Página 13 GARANTIE LIMITEÉ À VIE Le Vendeur garantit ce produit à vie, s’il est utilisé conformément aux instructions applicables, contre tout défaut de matière et de main-d’oeuvre. Si le produit présente un défaut de matière ou de main-d’oeuvre pendant cette période, le Vendeur s’engage à le réparer ou à...