1.1 These electropumps have been designed to recirculate
lightly treated water in swimming pools and spas, both private
and public.
1.2 Technical characteristics
Motor:
Power ratings: See nameplate ratings on electropump.
Insulation: Class E.
Operation: Continuous.
Protection: IP 54.
Current: Single phase and triphase (see nameplate ratings).
Consumption: See nameplate ratings.
Frequency: See nameplate ratings.
R.P.M: See nameplate ratings.
Shaft: Stainless steel.
Bearing: Armoured ball bearing.
Atmospheric temperature: Maximum 40ºC (BC) 50ºC (BCP).
Pump:
Water temperature: Max 50ºC
Maximum pressure: 2 BARS
Impeller model: Closed
Type of seal: Mechanical retainer.
Diffuser : Synthetic material (PP)
Impeller : Noryl with Fiber Glass
Pump Casing : Synthetic material (PP)
Filter lid for BCP model : Synthetic material
Aspiration diameter : Socket 90mm
Impelling diameter : Socket 90mm
2. GENERAL
2.1 Introduction
This handbook contains the necessary instructions for
installation, use and maintenance of the swimming pool
electropump. In order to obtain the maximum yield shown by
the manufacturer in the Description of Characteristics, it is
necessary to fulfil and follow correctly all the recommendations
given in this-Handbook. This will allow operation with a safe
and long-lasting piece of equipment. The equipment supplier
will furnish the user with complementary information, if
required.
2.2-Safety signs used in the handbook.
All instructions referring to possible risks to persons are
highlighted by the followings symbols:
Standard DIN 4844-W9
Danger in general
Standard DIN 4844-W8
Danger of electrocution.
Other instructions in relation to the functioning of the
equipment with which non-compliance could cause physical
damages are highlighted with the warning: ATTENTION
2.3 Nameplate ratings (EEC 89/392 P.1.7.4.A.) The
information given on the nameplate or other instructions affixed
by the manufacturer to the unit, must be strictly complied with.
The content of these plates can usually be found in this
Handbook (Chapter 1.2).
FIBERPOOL INTERNACIONAL
2.4 Liability. Failure to comply with the instructions given by
manufacturer in this handbook, in relation to the choice,
handling, installation, starting and maintenance of the unit,
shall release the manufacturer or distributor from all liability in
respect of accidents suffered by persons or damages caused
to other installations and, in addition, shall entail forfait of the
warranty.
2.5
manufactured in accordance with the necessary requirements
for safety and health set forth in Community Directives
89/392/EEC, 91/368/EEC (assimilated into Spanish Law by
Royal Decrees, 1435/1992 and 93/44/EEC).
3 GENERAL INSTRUCTIONS IN RELATION TO USER
SAFETY.
can only be guaranteed if it is used in accordance with the
diagrams show n on page 11-12 "Illustrations". It must never
exceed the working conditions and limits given in this
Handbook
Compliance with the provisions of Safety Standards in force in
each country is mandatory.
adequate for the use for which it is intended and that its
condition, installation, starting and subsequent use are correct.
See chapter 1 (Technical Characteristics).
be carried out in all cases with equipment disconnected from
the mains.
moved or repositioned. These operations will be carried out at
all times with the machine disconnected.
will not be performed where there is damp, and special care
must be taken for user's hands to be dry, and also with
footwear and surfaces with which the user is in contact.
functioning, are in movement or which could reach dangerous
temperatures, will be protected with cages or casings which
will prevent accidental contact with the same.
current, will be suitably insulated. Other metal parts of the
equipment will be correctly earthen.
from the manufacturer or those recommended by the
manufacturer. The use of others, or originals rectified by
others, are not permitted and release the manufacturer or
distributor from all liability.

4 PACKING, TRANSPORT AND STORAGE

4.1 ATTENTION. The manufactured supplies the equipment
protected in suitable packaging, so that it is not damaged
during transport or storage thus preventing its correct
installation and/or functioning.
Standard.
Our
swimming
3.1 Safety during operation of the machinery supplied
(chapter
1.2
3.2 Please ensure that the equipment selected is
3.3 Installation, repair and maintenance operations will
3.4 While the equipment is functioning, it cannot be
3.5 Pressing of the electrical on/off or safety elements
3.6 Those elements of the equipment which, when
3.7 Electricity conductors, or parts which could carry
3.8 Spare parts that may be necessary will be originals