Troubleshooting Notes

Attention: There will be a 10 second delay after the pump is powered
up before the motor starts. This will occur every time power is cycled.
Switch Blink Code
One blink – Pump problem
Pump shuts off
Two blink – System problem
Run dry
Pump is cycling
Pump won't start
Pump shuts off
* To bypass the leak detection feature, rocker switch provided must be
cycled 4 times consecutively.
U.S.A
UNITED KINGDOM
JAPAN
GERMANY
ITALY
Discover ITT at www.jabsco.com
The products described herein are subject to the Jabsco 3 year limited
warranty, which is available for your inspection upon request.
Les produits décrits ci-dessous bénéficient de la garantie limitée d'un an de Jabsco, que vous
pouvez consulter sur simple demande.
Die nachstehend beschriebenen Produkte unterliegen einer einjährigen Gewährleistung. Die
Gewährleistungsbedingungen können bei Jabsco angefordert werden.
I prodotti qui descritti sono coperti dalla garanzia Jabsco limitata di un anno, disponibile per la
visione su richiesta.
De hierin beschreven producten worden aangeboden met de beperkte Jabsco garantie van één
jaar. Deze is op aanvraag verkrijgbaar ter inzage.
För produkterna som beskrivs nedan utfärdar Jabsco ett års begränsad garanti, som vi kan
skicka till dig på begäran.
Los productos descritos en este folleto están respaldados por la garantía limitada de Jabsco por
un año, que está disponible para su lectura a pedido.
© Copyright 2010 ITT Corporation
Pump is drawing
high amps
Pump is too hot
Tank is empty
System leak
Under voltage/
over voltage
Over voltage/
under voltage
Pump or motor bearing seized.
The motors thermal protection will
shut the pump down if the tempera-
ture gets too hot. Wait for the pump
to cool down and cycle the power.
Pump will shut down after 3.5
minutes and will not restart until
power is cycled.
Pump will shut down if it cycles on
and off due to a system leak and will
not restart until power is cycled.
Pump will shut down if voltage is
below 9.5 volts.
Pump will shut down if voltage is
above 14.5 volts.