Automatic Water
System Pump
CAUTION
Installation/Mounting
Figure 2.
Horizontal
Horizontal
CAUTION
sure that the area where pump is installed is isolated from gas,
fuel tanks, electrical wiring looms or flammable substances.
Failure to do so may cause injury or death.
1: Select pump location. Pump
must be installed in a dry,
ventilated area.
2: Connect fittings supplied
with the pump to the vessels
plumbing. Use ½" (13mm)
I.D. flexible hose (preferably
braided or reinforced) to reduce
vibration through the plumbing
system (Figure 1). Use hose
clamps on the slip on barb hose
connectors.
Important: Install strainer pump inlet to
protect valves from debris.
3: Fasten pump to a flat surface. If mounting
vertically; install with pumphead down (Figure 2) Do not over
tighten screws to allow rubber mounts to absorb vibration.
4: Install inlet (A) and discharge (B) fittings. Firmly push slide
clips (C) forward to lock fittings in place. – Figure 3
Figure 3.
Inlet Strainer (A)
Figure 4.
Water
Tank
Do Not Plumb Autofill
to Pump Suction Line
Not For Continuous Duty, Intermittent
Duty Only
Installation Notes: To avoid the risk of fire. Be
City Water
Inlet
Vertical
Vertical
NOTE: Do Not Submerge
NOTE: Do Not Submerge
Figure 1.
Discharge (B)
Water
Heater
Check
Valve
Pumpgard
Strainer
Autofill Tank Valve,
Plumb to Tank