Gas Requirements
For Natural Gas Connection
Preparing:
1.
Turnoff gas supply, and then remove cap on gas
Supply side.
2.
Recommended: Install a shut-off valve on
gas supply side before installing the socket.
3.
Socket should be installed by an authorized
technician in accordance with the national fuel gas
code (NFF,A 54/ANSI223.1)
4.
Before inserting plug, turn on gas supply and leak
test all connections including the stem of the shut-off
valve and the opening of the socket. For best results,
use and ammonia-free soap & water solution.
Operating Instructions:
1.To connect, pushback socket sleeve.
Socket
Sleeve
Plug
LPGas
If your grill is for LF, G as, the regulator supplied is set for
an 11-in.Water column (WC} and is for use with LF, g as
only. The factory-supplied regulator and hose must be
used with a 20-lb. LF, g as tank.
Natural Gas
If your grill is for Natural Gas, it is set for a 7-in. water
column (WC} and is for use with Natural Gas only. Gas
pressure is affected by gas line size and the length of
gas
line run from
house gas
line. Follow
the
recommendations in the chart below.
From House to Grill
Distance
Tubing Size
Up to 25 ft.
3/8 in. diameter
26-50
ft.
1/2 in. diameter
51-100 ft.
2/z3 of the run: 3/4
in. diameter
1/3 of the run: 1/2 in. diameter
Over 101 ft.
3/4
in. diameter
2. Insert plug and release sleeve.
3. Pushplug until sleeve snaps forward. (Gas will flow
automatically. Failure to connect plug properly to
socket will inhibit gas flow to the appliance.)
To disconnect
1.
Pull Sleeve back. Pull plug out socket. (Gas is
automatically shut off.)
2.
Close shut-off valve and replace dust caps on socket
and plug.
23674-30800316