Disassembly And Cleaning - Legend Brands Dri-Eaz LGR 2800i Manual Del Propietário

Ocultar thumbs Ver también para Dri-Eaz LGR 2800i:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

damage. Call Dri-Eaz for the nearest Service Center at
800-932-3030.
Inspect filter. Replace if accumulation of dust and
debris is visible.
NOTICE: Replace used filters only with a new Dri-
Eaz filter (Dri-Eaz part no. FXXX). Other filter types
do not provide adequate filtration or airflow.
Monthly
Check coils. Dirty coils can cause the unit to overheat.
Clean when visibly dirty.
Check heat exchange block. Clean out with
compressed air only. Take care not to damage the block.
Inspect and clean the pump. To remove the
condensate pump unit:
SERVICING THE PUMP AND DRAIN PAN
To maintain proper operation, the pump and drain pan
assembly should be periodically removed and cleaned.
Follow these steps to clean the pump and drain pan
assembly:
Tools Needed
Philips screwdriver
Flat blade screwdriver
⅜ in. and
15
in. sockets and driver
16
Cleaning cloths

DISASSEMBLY AND CLEANING

1. Unplug unit, then remove the power cord from the
socket at the base of the unit. Remove pump hose at
quick-connect.
2. Remove filter.
3. Remove the two bolts from the upper front cover.
FIG. E: ELECTRIC BOX
ATTACHMENT SCREWS
1. After placing a firm support under the base of the unit, remove
the center hub cap and remove the axle nut. The wheel will now
slide off. 2. Remove the two screws (shown in the circles above) to
detach the electric junction box.
07-01674P F410, F411
4. Remove one bolt each from the upper back corner of
side covers A and B (see Fig. A)
5. Remove four bolts from the lower back panel. The
back/top panel may now be removed.
6. Remove lower back metal panel (unscrew the five
attachment screws).
7. Place a firm support under the base of the unit so that
the left wheel may be removed.
8. Using the flat blade screwdriver, carefully pry the
center hub cap loose from the left wheel. Use the
socket to remove the retaining nut and slide the wheel
off. See Fig. E, #1.
9. Remove the two electric box retaining screws (see
Fig. E, #2.).
10. Tilt the bottom of the electric box to the right and
slide outward (Fig. F). It is not necessary to disconnect
any electrical cables.
11. Remove drain hose from pump assembly and slide
pump and tray assembly out of the unit.
12. Lift pump body out of plastic catch tray.
13. Wipe or rinse off all surfaces of the plastic catch tray
with a damp cloth.
CLEANING THE PUMP AND PUMP TRAY
14. Remove the pump assembly from the pump tray and
set pump aside. Wipe or rinse out pump tray and wipe
dry.
15. Remove pumpout hose from the check valve outlet.
16. Unscrew check valve. Using needle nose pliers,
carefully remove bottom of check valve assembly by
inserting one side of pliers approximately ⅛ in. into hole,
grasp and pull out carefully. A small ball bearing should
fall out so be careful not to lose it. Inspect assembly for
debris in assembly and clean accordingly. Reinstall the
ball bearing and reinstall the check valve assembly.
FIG. F: ELECTRIC BOX LOCATION
After removing attachment screws (Fig. E), tilt the bottom of the
electrical box to the right and slide it out. Set aside. It is not necessary
to disconnect any electrical cables.
7
15
in.
16
Legend Brands, Inc.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dri-eaz lgr 3500iF410F411

Tabla de contenido