Operation
Display
The values will be shown with three digits, and with a setting you
can determine whether the temperature are to be shown in °C or
in °F.
Light-emitting diodes (LED) on front panel
There are LED's on the front panel which will light up when the
belonging relay is activated.
The three lowermost LED's will flash, if there is an error in the
regulation.
In this situation you can upload the error code on the display and
cancel the alarm by giving the uppermost button a brief push.
The controller can give the following messages:
E1
E6
E7
Error message
E8
E12
A1
A2
Alarm message
A43
A44
The buttons
When you want to change a setting, the two buttons will give you
a higher or lower value depending on the button you are push-
ing. But before you change the value, you must have access to the
menu. You obtain this by pushing the upper button for a couple
of seconds - you will then enter the column with parameter codes.
Find the parameter code you want to change and push the two
buttons simultaneously. When you have changed the value, save
the new value by once more pushing the two buttons simultane-
ously.
Gives access to the menu (or cutout an alarm)
Gives access to changes
Saves a change
Examples of operations
Set reference temperature
1. Push the two buttons simultaneously
2. Push one of the buttons and select the new value
3. Push both buttons again to conclude the setting
Set one of the other menus
1. Push the upper button until a parameter is shown
2. Push one of the buttons and find the parameter you want to
change
3. Push both buttons simultaneously until the parameter value is
shown
4. Push one of the buttons and select the new value
5. Push both buttons again to conclude the setting
EKC 368
Errors in the controller
Change battery in timer. Set the timer.
Cut-out Sair
Shortcircuited Sair
Analog input signal is outside the range
High-temperature alarm
Low-temperature alarm
Check supply voltage for the step engine
Battery alarm (no voltage or too low voltage)
Instructions RI8JC353 © Danfoss 10/2009
English
Menu survey
Function
Normal display
Shows the temperature at the room sensor
Give the lower button a brief push to see the
temperature at the defrost sensor
Reference
Set the required room temperature
Temperature unit
External contribution to the reference
Correction of the signal from Sair
Correction of the signal from Sdef
Start/stop of refrigeration
Alarm
Upper deviation (above the temperature setting)
Lower deviation (below the temperature setting)
Alarm's time delay
Monitoring of battery
Defrost
Defrost method (ELECTRICITY/GAS)
Defrost stop temperature
Max. defrost duration
Drip-off time
Delay for fan start or defrost
Fan start temperature
Fan cut in during defrost (yes/no)
Delay for temperature alarm after defrost
Regulating parameters
Actuator type: 1=KVS15, 2=KVS28-35, 3=KVS42-54
4=User defined via AKM / For Danfoss only
Setting of menu only when r12 = off.
P: Amplification factor Kp
I: Integration time Tn (600 = off )
D: Differentiation time Td (0 = off )
Transient phenomenon
0: Fast cooling
1: Cooling with less underswing
2: Cooling where underswing is unwanted
Start-up time after hotgas defrost
Miscellaneous
Controller's address
ON/OFF switch (service-pin message)
Define input signal of analog input
0: no signal
1: 0 - 10 V
2: 2 - 10 V
Set supply voltage frequency
Service
Read temperature at the Sair sensor
Read regulation reference
Read value of external voltagt signal
Read temperature at the Sdef sensor
Read status of input DI
Read duration of defrost
Opening degree of the valve
*) This setting will only be possible if a data communication module has been
installed in the controller.
Factory setting
If you need to return to the factory-set values, it can be done in this way:
- Cut out the supply voltage to the controller
- Keep both buttons depressed at the same time as you reconnect the supply voltage
SW =1.6x
Fac.
Para-
Min.
Max.
set-
meter
ting
-
°C
-
°C
-
-70°C 160°C
10
r05
°C
°F
°C
r06
-50 K
50 K
0
r09
-10,0 K 10,0 K
0
r11
-10,0 K 10,0 K
0
r12
OFF
On
On
A01
0
50 K
5
A02
0
50 K
5
A03
0
180 min 30
A34
Off
On
Off
d01
Off
GAS
Off
d02
0
25°C
6
d04
0
180 min 45
d06
0
20 min 0
d07
0
20 min 0
d08
-15°C 0°C
-5
d09
no
yes
no
d11
0
199 min 90
n03
1
4
1
n04
1
50
4
n05
60 s
600 s
120
n06
0 s
60 s
0
n07
0
2
1
n08
0 min 20 min 1
o03* 1
60
0
o04* -
-
Off
o10
0
2
0
o12
50 Hz 60 Hz
50
u01
°C
u02
°C
u07
V
u09
°C
u10
on/off
u11
m
u23
%
5