Step 3: Getting started
Before powering the unit on, make all
audio and digital connections.
Turn on the power.
The default confi guration is active when
all status LEDs above the CONFIG button
are off (see Seq . 1 in Operation
Mode Chart). If your application requires a diff erent
output setup, press and hold the CONFIG button to
enter confi guration mode. While pressing the
CONFIG button, turn the SELECT/ADJUST knob to
scroll through the items. You can select from the
following options:
• Engage the SN MASTER function to designate
the master unit when using two DL16 units in a
standalone snake application. This is available in
4 modes, 44.1 kHz and 48 kHz, each with Splitter
mode engaged or disengaged.
• Engage the SPLITTER function to send the
16 local input signals directly to the ADAT OUT
and P16 jacks. When the SPLITTER function is
disengaged, the ADAT OUT jacks carry AES50
channels 17-32 and P16 carries channels 33-48.
• Select whether the OUTPUT jacks 1-8 carry the
AES50 channels 1-8 (LEDs off ), 9-16, or 17-24 by
engaging the OUT +8 or OUT +16 function.
NOTE: Please verify that your specifi c AES50 connections provide stable operation prior to using the products
in a live performance or recording situation. The maximum distance for AES50 CAT5 connections is 100 meters
(330 feet). Please consider using shorter connections where possible for gaining safety margin. Combining
2 or more cables with extension connectors can reduce the reliability and maximum distance between
AES50 products. Unshielded (UTP) cable may work well for many applications, but entails an additional risk
for ESD issues. We guarantee, that all our products will perform as specifi ed with 50 m of KLARK TEKNIK
NCAT5E-50M, and we recommend using cable of similar quality, only. KLARK TEKNIK also off ers the very cost-
eff ective DN9610 AES50 Repeater or DN9620 AES50 Extender for situations where extremely long cable runs
are required.
Release the CONFIG button to exit
confi guration mode. See the Operation
Mode Chart for more details.
Repeatedly press the SELECT/ADJUST
knob until the left side of the display
shows "In". Turn the SELECT/ADJUST
knob to select one of the inputs 1-16.
Press the 48 V button to toggle the
selected channel's phantom power
on/off , if necessary.
Press the GAIN button. The button will
light, and the gain can now be adjusted
with the SELECT/ADJUST knob. Turn the
knob to the right until the loudest peaks in your
speaking or playing cause the -9 dB LED to light
briefl y in the meter.
With headphones connected to the
PHONES jack, turn the adjacent
MONITORING LEVEL knob up to a
comfortable listening level.
Specifi cations
Processing
A/D converters (8-channel, 24-bit @ 44.1 / 48 kHz)
D/A converters (stereo, 24-bit @ 44.1 / 48 kHz)
Networked I/O latency
(stagebox in > console processing* > stagebox out)
Connectors
XLR inputs, programmable mic preamps
XLR outputs
Phones outputs, ¼ " TRS
AES50 ports, SuperMAC, NEUTRIK etherCON
P-16 connector, Ultranet (no power supplied)
MIDI inputs / outputs
ADAT Toslink outputs (2 x 8 Ch)
USB type B, rear panel, for system updates
Mic Input Characteristics (MIDAS PRO)
THD + noise, @ unity gain, 0 dBu out
THD + noise, @ +40 dB gain, 0 dBu out
Input impedance XLR, unbal. / bal.
Non clip maximum input level, XLR
Phantom power, switchable per input
Equivalent input noise @ +40 dB gain, (150R source)
CMRR, XLR, @ unity gain (typical)
CMRR, XLR, @ 40 dB gain (typical)
Input/Output Characteristics
Frequency response @ 48 kHz sample rate
Dynamic range, analogue in to analogue out
A/D dynamic range, preamp and converter (typical)
D/A dynamic range, converter and output (typical)
Cross talk rejection @ 1 kHz, adjacent channels
Output level, XLR, nom./max.
Output impedance, XLR, unbal. / bal.
Phones output impedance / level
Residual noise level, out 1-8 XLR, unity gain
Indicators
Display
Front status LEDs
Meter
Rear panel
Power
Switch-mode autorange power supply
Power consumption
Physical
Dimensions
Weight
* incl. all channel and bus processing, excl. insert eff ects and line delays
Quick Start Guide
114 dB dynamic range (A-weighted)
120 dB dynamic range (A-weighted)
1.1 ms
16
8
1 (mono)
2
1
1 / 1
2
1
< 0.01% unweighted
< 0.03% unweighted
10 kΩ / 10 kΩ
+23 dBu
48 V
-125 dBu, 22 Hz – 22 kHz unweighted
> 70 dB
> 90 dB
0 to -1 dB 20 Hz to 20 kHz
107 dB (22 Hz - 22 kHz unweighted)
109 dB (22 Hz to 22 kHz unweighted)
110 dB (22 Hz - 22 kHz unweighted)
100 dB
+4 dBu / +21 dBu
50 Ω / 50 Ω
40 Ω / +21 dBu (mono)
-86 dBu, 22 Hz - 22 kHz unweighted
4-digit, 7-segment, LED
AES50-A, red/green
AES50-B, red/green
HA Locked, red
SN Master, green
Splitter, orange
Out +16, orange
Out +8, orange
Sig, -30 dB, -18 dB,
-12 dB, -9 dB, -6 dB,
-3 dB, Clip
Splitter mode, orange
100-240 V (50/60 Hz)
45 W
482 x 225 x 89 mm (19 x 8.9 x 3.5")
4.7 kg (10.4 lbs)
15