Motion Sensor Quartz
Security Light
Model SL-5309
The Motion Sensor Quartz Security Light turns on 300
watts of quartz-halogen lighting when motion is detected
and then, after a selectable period of time, automati-
cally turns the lighting off. The built-in photocell keeps
the lighting off during daylight hours.
This package includes:
Sensor
Light Control
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must
be wired through a switch – not a dimmer or other
electronic switch.
• Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
• The backplate has knockouts so the sensor can be
mounted on most junction boxes.
• In some applications a universal adaptor plate may
be needed. Adaptors are available at Home Centers
and Electrical Supply Stores.
OPERATION
Mode:
On-Time
Test
5 Seconds
Auto
1, 5, or 10 Min
Manual
Until Dawn*
* resets to Auto Mode at dawn.
© 2007 HeathCo LLC
Cover Plate
Gasket
Cover
4 Screws
Plate
(2 sizes)
Halogen
Bulb
3 Wire
Long Bolt
Connectors
Works:
Day Night
x
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5, or
10 minute position.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time (1
AUTO mode.
INSTALLATION
For easy installation, select an existing light with a wall
switch for replacement.
x
x
x
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
MANUAL MODE
1 Second OFF
... back on.
Move ON-TIME Switch
to 1, 5, or 10 minutes
Flip switch off for
one second then
back on*
/
min.) the control will be in the
1
2
❒ Attach the lamp arm to
the backplate arm and
secure with the long
bolt.
Note: When tightening the
arm screw, pull on the wires
to make sure the wires are not
pinched by the joint.
then...
595-5496-07

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Zenith Heath SL-5309

  • Página 1 TEST ON-TIME Put the ON-TIME switch on the bottom of the sensor in the TEST position. 10 5 1 TEST Motion Sensor Quartz AUTO Security Light ON-TIME Put the ON-TIME switch in the 1, 5, or 10 minute position. Model SL-5309 10 5 1 TEST The Motion Sensor Quartz Security Light turns on 300 watts of quartz-halogen lighting when motion is detected...
  • Página 2 nstaLLation eLaMping ❒ When re-lamping, turn power off and let the fixture ❒ Drill out the holes if cool. needed to mount the CAUTION to avoid fire or burn hazards: backplate to the junction box. • Allow fixture to cool before touching. The bulb and fixture operate at high temperatures.
  • Página 3 TEST AND ADJUSTMENT ❒ Loosen the clamp screw in Clamp the sensor ball joint and gently Screw ❒ Turn on the circuit breaker and light switch. rotate the sensor to aim. NOTE: Sensor requires about 1 minutes to calibrate ❒ Walk through the coverage Ball before it will detect motion.
  • Página 4: Troubleshooting Guide

    TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Light will not come 1. Light switch is turned off. Light stays on 1. The halogen lamp is positioned too 2. Halogen lamp is loose or burned continuously. close to the light control’s sensor out.
  • Página 5: Detector De Movimiento Y Control De Faro Halógeno De Cuarzo

    PRUEBA ON-TIME Ponga el interruptor de tiempo (ON- Detector de Movimiento y TIME), al fondo del detector, en la posición de prueba (TEST). 10 5 1 TEST Control de Faro Halógeno AUTOMATICO de Cuarzo ON-TIME Ponga el interruptor de tiempo (ON- TIME) en la posición de 1, 5 ó...
  • Página 6: C Onecte E L C Ontrol De L Uz

    ❒ Perfore los agujeros que se necesiten para montar CORRECTO INCORRECTO la placa de atrás a la caja La luz halógena debe estar de empalmes. montada horizontalmente (+/- 4°). nstaLaCión aMBio oMBiLLa oneCte ontroL de ❒ Cuando cambie la bombilla, apague la energía y deje que el aparato se enfríe.
  • Página 7: Prueba Y Ajuste

    PRUEBA Y AJUSTE ❒ Afloje el tornillo de la gram- Tornillo pa en la unión esférica del Sujetador ❒ Prenda el cortacircuitos y el interruptor de luz. detector y gire suavemente el detector para apuntar. NOTA: El detector tiene un período de cerca de 12 Unión minutos de calentamiento antes de detectar Esférica...
  • Página 8: Guia De Investigacion De Averias

    GUIA DE INvESTIGACION DE AvERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La luz no se La luz se queda 1. El interruptor de luz está apagado. 1. La lámpara está colocada demasiado enciende. prendida con- 2. La lámpara halógena está floja o fundida. cerca al detector o está...
  • Página 9 ESSAI ON-TIME Amener en position d’essai (TEST) Luminaire de sécurité au quartz l’interrupteur de temps en circuit (ON- TIME) du bas du détecteur. 10 5 1 TEST à détecteur de mouvement AUTOMATIQUE Modèle SL-5309 ON-TIME Amener l’interrupteur de temps en Le luminaire de sécurité...
  • Página 10 L’ nstaLLation eMpLaCeMent aMpouLe ❒ Avant de remplacer l’ampoule, couper l’alimentation ❒ Percez les trous néces- et laisser refroidir le luminaire. saires au montage de la plaque arrière à la boîte AvERTISSEMENT: Pour éviter les risques de de jonction. brûlure ou d’incendie •...
  • Página 11: Essais Et Réglages

    ESSAIS ET RÉGLAGES ❒ Desserrer la vis de blocage Vis de de la rotule et faire pivoter le blocage ❒ Mettre en circuit le disjoncteur et l’interrupteur détecteur pour pointer. d’éclairage. ❒ Marcher dans la zone de Rotule REMARQUE: Le capteur doit se réchauffer 1 minute couverture et noter à...
  • Página 12: Guide De Dépannage

    GUIDE DE DÉPANNAGE SYMPTÔME CAUSE POSSIBLE SYMPTÔME CAUSE POSSIBLE L e s l a m p e s Les lampes 1. L’interrupteur d’éclairage est en posi- 1. Un projecteur se trouve trop près ne s’allument restent allu- tion hors circuit. du détecteur de la commande pas.