RFIM-20B, RFIM-40B
Wireless contact converter
EN
Convertidor inalámbrico de contactos
ES
Technical parameters /
Especifi caciones técnicas
Supply voltage:
Battery life:
Transmission indication / function:
Number of inputs:
Transmitter frequency:
Signal transmission method:
Range in free space:
Other data
Operating temperature:
Operating position:
Terminals
Length of terminals:
Resist.of connection between ter-
minals - for switched on button:
- for disconnected contact:
Mounting:
Protection:
Contamination degree:
Dimensions:
Weight:
Open contact voltage:
Length of cable to contact:
Related standards:
* RFIM-40B: on condition, that contact is permanently closed- battery life is approx. 1 month.
Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing.
Installation and connection can be carried out only by a person with adequate professional qualifi cation upon
understanding this instruction manual and functions of the device, and while observing all valid regulations.
Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any
sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It
is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting
installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing
observe safety regulations, norms, directives and professional, and export regulations for working with electrical
devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe
correct location of RF components in a building where the installation is taking place. RF Control is designated only
for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not
be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is
then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an
obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control.
ELKO EP ESPAÑA, S.L. | C/ Josep Martinez 15a, bj | 07007 Palma de Mallorca | e-mail: info@elkoep.es | Tel.: +34 971 751 425 | Fax: +34 971 428 076
Made in Czech Republic
Tensión de alimentación:
Duración de la batería:
Indicación de transmisión:
Número de entradas:
Frecuencia:
Modo de transmisión de señal:
Rango al aire libre:
Más información
Temperatura de funcionamiento:
Posición de funcionamiento:
(CY wire, cross-section)
:
Salida (hilo CY, sección):
Longitud de los hilos:
Resistencia entre terminales
- para el botón activado:
- contacto abierto:
Montaje:
Protección:
Grado de contaminación:
Dimensiones:
Peso:
Tensión del contacto abierto:
Longitud del cable al contacto:
Normas conexas:
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: elko@elkoep.com | Support: +420 778 427 366
www.elkoep.com / www.elkoep.es
RFIM-20B
1 x 3V battery / pila CR 2477
2 x 3V battery / pila CR 2032
5 years / años *
orange / naranja LED
2
866 MHz, 868 MHz, 916 MHz
unidirectionally addressed message / mensaje dirigida unidireccionalmente
up to / hasta 200 m
-10 ... +50 °C
any / cualquiera
2
4 x 0.75 mm
90 mm
< 300 Ω
> 10 kΩ
free at lead-in wires / libre en los cables de conexión
IP30
2
49 x 49 x 13 mm
45 g
pulse / pulso 12 V 
max. 100 m of parallel lines /
máx.100 mts de linea en paralero
EN 60669, EN 300220, EN 301489 R&TTE Directive, Order. No 426/2000 Coll. (Directive 1999/EC)/
EN 60669, EN 300 220, EN 301 489 directiva RTTE, NVč.426/2000Sb (directiva 1999/ES)
* RFIM-40B: en el contacto permanentemente cerrado la duración de la batería es de
aproximadamente 1 mes.
Advertencia:
En la instalación de iNELS RF Control debe haber una distancia mínima entre las diferentes unidades
de un centímetro.
Entre los diferentes ordenes debe pasar al menos 1s.
Advertencia
El manual de uso está dirigido para la instalación y el usuario del dispositivo. Manual siempre está incluido en
embalaje. La instalación y conexión puede realizar sólo personal con adecuadas cualifi caciones profesionales, de
conformidad con todas las regulaciones aplicadas, y que está perfectamente familiarizado con estas instrucciones
y funciones del dispositivo. Función del dispositivo también depende del transporte, almacenamiento y la
manipulación. Si se observa cualquier signo de daño, deformación, mal funcionamiento o pieza que falta, no instale
este producto y devolvelo al vendedor. Con el producto y sus componentes debe ser tratado después de su vida
útil como con residuos electrónicos. Antes de iniciar la instalación, asegúrese de que todos los cables, partes o
terminales conectados están sin la conexión a la red. En el montaje y el mantenimiento se deben observar las
normas de seguridad, normas, directivas y reglamentos para trabajar con equipos eléctricos. No toque las partes
del dispositivo que están conectadas en la red - puede producir peligro de vida. Debido a la transmisibilidad de la
señal RF, observe la correcta ubicación de los componentes RF en un edifi cio donde la instalación se lleva a cabo. RF
Control está diseñado para montaje en interiores, las unidades no están diseñados para la instalación en exteriores
y espacios húmedos, no se pueden instalar en cuadros eléctricos de metal y en cuadros eléctricos plásticos con
puerta de metal - lo que empeora transmisividad de la señal RF. RF Control no se recomienda para el control de
dispositivos que ofrecen funciones vitales o para controlar dispositivos tales como bombas, el. calentadores sin
termostato, ascensores, montacargas, etc. - Señal de radiofrecuencia puede estar bloqueado por una obstrucción,
interferida, la batería del controlador puede estar ya sin energía, etc. y por lo tanto el control remoto puede ser
incapacitado.
02-45/2015 Rev.3
RFIM-40B
red / rojo LED
4
2
6 x 0.75 mm
50 g
3 V
max. / máx. 5 m
3/3

Publicidad

loading

Este manual también es adecuado para:

Rfim-40b