9.
Before replacing dome, ensure that the gasket is properly seated on the die-
cast base. Place the dome over the base, aligning the recesses inside the dome lip with the
four pins on the base. Push down on the dome and turn clockwise until it locks in place
(approximately 3/4-inch)
10. Replace the screw in the bottom of the dome.
11. Reassemble the light and test for proper operation.
C.
Cleaning Enclosure.
The circuit must be turned OFF and allowed to cool to the surrounding ambient
temperature before cleaning.
The fixture should be cleaned periodically to maintain maximum light output.
Only mild, non-abrasive cleaning agents should be used. The dome should be regularly
inspected for cracks and chips, and, if damaged, must be replaced.
D.
Service.
Federal Signal will service your equipment and provide technical assistance with
any problems that can not be handled locally by Federal Signal's Distributor or Manufacturer
Representative.
Any units returned to Federal Signal for service, inspection, or repair must be
accompanied by a Return Material Authorization number with a brief explanation of the
service being requested and/or the nature of the malfunction. This R.M.A. can be obtained
from the local Federal Signal Distributor or Manufacturer's Representative.
Address all communications and shipments to:
Federal Signal Corporation
Electrical Products Division
Service Department
2645 Federal Signal Drive
University Park, IL 60466-3195
Description
Dome, Clear
Flash Tube/Trigger Coil Assy.
Circuit Board Assy., 12-24VDC
Circuit Board, Inrush Current, 24VDC
NOTE
Part Number
8550326A-02
K8107177A
K2001202C-01
K2001918A
-5-