CALIBRATION/ZEROING
Calibrate your ROTOR Power for an accurate power
measurement. ROTOR Power should be calibrated
after any chainring, frame, or pedal changes.
A second calibration is recommended after the first
30 hours of use.
To zero your ROTOR Power:
1. Activate the system and place the right crank
in 6 o´clock vertical position.
Do not move your cranks during steps 2, 3, 5
and 6.
2. Push "CALIBRATE" button on your ANT+ .
(Menu: Settings\Bike settings\Bike profiles\"Your profile"\
ANT+Power)
3. Read the feedback value for the drive side
crank from your device. Value should be
between 100-3900.
05
QUICK GUIDE - CALIBRATION/ZEROING
TM
In order to save energy the "CALIBRATE" command
is admitted only within 60 seconds from startup or
last valid power readings.
For more information read the USER MANUAL or visit our web:
www.power.rotorbike.com
4. Repeat step 1 for left crank.
5. Repeat step 2 to send the
"CALIBRATE " signal.
6. Read the feedback value for
the non-drive side crank from
our device. Value should be
between: 4200-8100.
WARNING!