Jung FMAS26UP Instrucciones De Servicio página 7

Actuador pulsador/de conmutación enet 2 fases mini
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Actuador pulsador/de conmutación eNet 2 fases mini
Manual commissioning
Repeater mode
Channel settings
Parameters
Switch-on delay
Switch-off delay
82579133
J0082579133
On, Off
Basic setting: On
On, Off
Basic setting: Off
Setting options, Basic set­
ting
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
7/11
Disables manual commissio-
ning for all device channels. In
the "Off" setting, the device
cannot be reset to the factory
setting.
In addition to its other func-
tions, the device can be used
as a repeater. In the "On" set-
ting, the device repeats all the
received telegrams.
Explanations
The load switches on after a
delay. Repeated switch-on
commands restart the delay ti-
me. If the load has not yet
been switched on due to the
delay when a switch-off com-
mand comes, then the load
will remain off.
In Flashing operating mode,
the pause time is set using
this parameter.
Comment: The set times apply
to operation using radio trans-
mitters. The relay is switched
immediately when the Prog
button is pressed.
The load switches off after a
delay. Repeated switch-off
commands restart the delay ti-
me. If the load has not yet
been switched off due to the
delay when a switch-on com-
mand comes, then the load
will remain on.
In Flashing operating mode,
the pulse times are set using
this parameter.
Comment: The set times apply
to operation using radio trans-
mitters. The relay is switched
immediately when the Prog
button is pressed.