UR2-WE
Dual channel universal receiver
for Enforcer inputs and keyfobs
E N G L I S H
Environmental Class II
Output A and Output B:
Each output allows a maximum of 10x Wireless Inputs and 6x Wireless
Keyfobs to be learnt. The relays will wire directly to an input on the
control panel (normally open or normally closed).The outputs should be
connected to an input programmed according to the device learnt (e.g.
Keyswitch input for keyfobs, or Intruder input for wireless devices)
Fault Output:
This output will activate if there are any of the following faults:
Low Battery / Jamming / Supervision / Tamper
The output should be connected to an input programmed as 'Fault'.
Arm / Disarm Status:
In order to receive alarm events from learned devices, the 'ARM' terminal
should be connected to an output that monitors the ARM/DISARM status of
the control panel. The shown dip switch is used to select 0v or 12v applied
when the control panel is armed.
PIR's will only trigger a channel relay if the UR2 is in an Armed State.
Learning Inputs:
It is recommended that all inputs are learnt to one output (e.g. OUTPUT A)
and all keyfobs are learnt to the other output (e.g. OUTPUT B) -A dot next
to the letter/number indicates that an Input is connected to OUTPUT B.
Learning Keyfobs:
If learning keyfobs, the control panel input should be programmed as a
keyswitch.
Signal Strength Indicator:
Shows the following for each input learned:
A
B
C
':
'
':Excellent. '
':Good. '
':Bad. '
Waiting for response/out of range
Event Log /History: (Events display in realtime AND in Event logs)
Clearing the Event Log
Deleting Inputs
Deleting Keyfobs
Pulse Outputs:
I
Keyfob: Pressing
,
or
on the keyfob will activate the relay for the
pulse time (3 or 60 seconds).
Input: The output will activate for the pulse time (3 or 60 seconds) after
an input has activated. The pulse time will only be reset once all inputs
are in a closed state.
II
Pressing
will display the UR2 status
RED LED = ARMED, GREEN LED = DISARMED, ORANGE LED = FAULT
Toggle Outputs:
Keyfob:
Pressing only the
button on the keyfob will activate the relay.
Pressing only the
button will deactivate the relay.
I
Pressing
will display the error LED (blinks orange 4 times).
Input: The output will activate after an input has activated. The output
will only be reset, when either the same input is activated again, or a
different input is activated.
II
Pressing
will display the UR2 status (same as pulse mode).
Walk Test Mode:
M
The channel relay will open for 3 seconds and then the relay will close
again after a successful walk test.
Technical Information Summary:
Supply Voltage:
9V – 15V
Current Consumption:
80mA (min) – 400mA(max, all outputs active)
Output A:
3A @ 30VDC
Output B:
3A @ 30VDC
Fault:
3A @ 30VDC
Arm / Disarm status:
0V (0V ARM), 9-15V (12V ARM)
Radio Frequency:
868MHz, FM Transceiver Narrow Band
Dimensions Plastic Box:
173x125x32mm
Dimensions PCB:
135x90x15mm
Operational Temperature:
-10°C to +50°C
Storage Temperature:
-40°C to +80°C
Humidity:
85% @ 25°
Product Information
For electrical products sold within the European Community. At the end of the electrical products
life, it should not be disposed of with household waste. Please recycle where facilities exist. Check
with your Local Authority or retailer for recycling advice in your country.
To prevent possible damage to components, any static charge on your body needs to be eliminated
before touching the inside of the unit. This can be accomplished by touching some rounded/earthed
metallic conductor such as a radiator/pipework immediately before handling the product.
Warranty
This product is sold subject to our standard warranty conditions
and is warranted against defects in workmanship for a period of
two years. In the interest of continuing care and design, Pyronix
Ltd reserves the right to amend specifications, without giving
prior notice.Please see the control panels programming manuals
for further information.
( 0845 6434 999 (UK). +44(0)1709 535 225
START
12V
0V
12V
ARM
0V
ARM
12V
0V
(FAST)
(VELOCE)
0
Example Disarm Status
after Alarm (Output A)
Signal Strength Indicator:
* customer.support@pyronix.com
 www.pyronix.com
OUTPUT A & B Wiring:
POWER SUPPLY
N/O (Normally Open)
+12VDC
Supply
OUTPUT
(A/B)
FAULT OUTPUT Wiring:
N/O (Normally Open)
FAULT
Learning Inputs:
ARM / DISARM:
Control
Panel
UR2-WE
(SLOW)
(LENTO)
1
DISPLAYS EVENTS IN ORDER ONCE DISARMED
MOSTRA GLI EVENTI ORDINE UNA VOLTA DISARMATO
≤300s
0-9
≤300s
≤300s
Pyronix Limited,Pyronix House,Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
= ALARM
= TAMPER
N/C (Normally Closed)
N/O DEOL
OUTPUT
OUTPUT
(A/B)
(A/B)
= ALARM
= TAMPER
N/C (Normally Closed)
N/O DEOL
FAULT
FAULT
0-9
>5s
Learning Keyfobs:
>5s
A-F
15s
N/C DEOL
OUTPUT
(A/B)
N/C DEOL
FAULT
RINS1702-4

Publicidad

loading

Resumen de contenidos para Pyronix UR2-WE

  • Página 1 This product is sold subject to our standard warranty conditions and is warranted against defects in workmanship for a period of two years. In the interest of continuing care and design, Pyronix Ltd reserves the right to amend specifications, without giving prior notice.Please see the control panels programming manuals...
  • Página 2 UR2 - Inserito Pulse Outputs: Toggle Outputs: (RELAY) (RELAY) (RELAY) (RELAY) Walk Test Mode: etc.. . Beep TAMPER ( 0845 6434 999 (UK). +44(0)1709 535 225 * customer.support@pyronix.com  www.pyronix.com Pyronix Limited,Pyronix House,Braithwell Way, Hellaby, Rotherham, S66 8QY, UK RINS1702-4...
  • Página 3 περίοδο δύο ετών. Η PYRONIX Ltd διατηρεί το δικαίωμα να τροποποιήσει τις προδιαγραφές, προς designu, Pyronix Ltd rezerwuje sobie prawo do zmiany specyfikacji bez wcześniejszego характеристики, без...
  • Página 4 En nuestro interés por el cuidado y hibamentességre (az elemek kivételével) 2 év garancia érvényes. A folyamatos termékfejlesztés desarrollo continuos, Pyronix Ltd se reserva el derecho de modificar las especificaciones sin previo érdekében a Pyronix Ltd fenntartja a jogot a műszaki jellemzők módosítására előzetes értesítés aviso.