8863H-All_Manuals 3/19/15 3:25 PM Page 22
INITIAL SETTING
Initial Setting Instruction
The instrument has several settings for your option to meet different
requirements of measuring. After your purchase and before your
operation, do the initial setting for the instrument.
Item Setting
No.
Item
Reading resolution
1
(minimal reading
display unit)
2
Sound function
3
Angle unit
Automatic
4
Shut-off
Measuring mode for
5
Vertical Angle
Tilt sensor
6
7
Data transmission
22
Description
Setting 0
40-6936
1"
Confirming sound
every 90º
Setting
Selecting angle display
unit DEG, GON, MIL
DEG
Setting
Setting interval for
0
automatic shut-off
OFF
without an operation
Setting measuring
Setting 0
mode for vertical angle
vertical angle
Set tilt function
Set data transmission
function
Parameter Setting
Setting 1
2"
Setting 0
Setting 1
OFF
Setting
0
1
GON
Setting
Setting
1
2
10 min
20 min
Setting 1
zenith angle
Setting 0
Setting 1
OFF
Setting 0
Setting 1
OFF
©2015 Johnson Level & Tool - Rev. 1
Setting 2
5"
ON
Setting
2
MIL
Setting
3
30 min
Setting 2
height angle
ON
ON